10 Keyboard Operations
10.1 Video Switching Control
1. Manual switching
To display a video in a certain monitor.
OPERATION: Press X CAM
(X: 1-32 ,camera ID; 1-CAM1 32-CAM32)
EXAMPLE: to display CAM4 to the current monitor,the opera-
tion is:
Press
4 CAM.
2. Choose monitor
OPERATION: Press X MON
(X: 1-7, monitor ID; 1-MON1 7-MON7)
EXAMPL E: to choose MON4 as the current monitor, the op-
eration is:
Press
4 MON.
3. Camera sequential scan
1) Set scan range
To display video s of cam eras by numeric se quence w ith
switching on the current monitor, OPERATION: Press
X PREV
Y NEXT.
(X- start camera ID, Y-end camera ID)
If x=y: invalid command
If x>y:scan from x, one by one to y with areverse sequential
turn, lastly go back to x and cycle.
If x<y: scan from x, one by one to y with a forward sequential
turn, lastly go back to x and cycle.
NO TE: X,Y m ust be se t to gethe r. If use r do es no t se t
t h e n u m b e r s , t he s y s te m w i ll a d o pt d e f au l t
se que nc e 1- 32. The num b e rs m ay be 1- 32, 1- 57,
1- 82, 1- 96, 1- 128 w ith diffe re nt c o nfigure .
EXAMPLE: to switch No.3 camera to No.8 camera
Operation: press : 3 PREV 8 NEXT
2) Activate camera sequential scan
OPERATION: Press
SHIFT X SCAN
(X-dwell time in second for each camera video, 1-255 )
EXAMP LE: to run camera se que ntial scan on the curre nt
monitor with dwell time as 3 seconds, the operation is:
Press SHIFT 3 SCAN.
3) Stop camera sequential scan
OPERATION: press SHIFT 0 SCAN
4. Previous camera
To display the previo us c am era vide o by ID num be r
sequence, press PREV.
5. Next camera
To display the next camera video by ID number sequence,
press NEXT.
6. Salvo switch
To run the programmed salvo switch, the operations are as
follows.
1)
Set dwell time
OPERATION: Press SHIFT X DWELL.
(X-dwell time in second for each step, 1-255)
NO TE: Th e d e fa ult dw e ll tim e f o r e ac h s te p is 2
se c o n ds. The se t dw e l l tim e i s e ffe c t ive fo r e ac h
salvo sw itc h se que nc e gro up (1- 16). Eve n if a salvo
sw i tc h s e que nc e is runni ng, t he us e r c an se t the
dw e ll tim e .
2)
Activate salvo switch sequence
OPERATION: Press SHIFT X PATTERN.
(X- salvo switch sequence group number, 1-16)
NO TE: The se que nc e group m ust be a pro gram m e d
o ne , o the rw ise y o u w ill he ar a so und o f B E EP and
no o pe ratio n is ac tivate d.
3) Stop salvo switch sequence
OPERATION: Press
SHIFT 0 PATTERN.
7. Standard sequence switch
1)
Activate standard sequence switch tour: to run the tour on a
certain monitor (refer to 7.5 for program setup).
OPERATION: Press
X MON SHIFT Y TOUR.
(X- 1-7, monitor number; Y- 1-30, sequence group number)
EXAMPLE: to run sequence group 3 on MON2, the operation
is: Press
2 MON SHIFT 3 TOUR.
The sequence group must be a programmed one.
2) Exit standard sequence switch tour
OPERATION: Press X MON SHIFT 0 TOUR
(X- 1-7, monitor number)
EXAMPLE: to exit running standard sequence tour on MON2,
the operation is:
Press