11
2.
To install the Cell Unions, cut out a section of pipe at the desired installation location.
Clean parts and plumbing with PVC Primer to prepare the pipe ends and interior of
Unions. Place the Threaded Collars over the pipe ends. Using plumbing Solvent
Cement, glue one Union to the pipe end.
3.
Hold the Cell and second Union up to the first, to gauge the correct distance before
gluing the second Union to the remaining pipe end. Allow sufficient time for glue to
dry.
Ensure that the O-rings are fitted to the Unions. Place the Electrolytic Cell between the
Unions and tighten the Collars onto the Cell. For a watertight seal, do not over-tighten the
Collars, and only tighten them by hand.
When using a Variable-Speed or Multi-Speed pump on a low speed setting, the cell
should be inverted in order to ensure adequate flow & efficient chlorine production.
Install Control Unit
:
The BLSC control must be mounted a minimum of 5 ft. (2 meters) horizontal distance (or
more if local codes require) from the pool/spa. The control is designed to mount vertically
on a flat surface facing downward. Because back of enclosure also acts as a heat sink
(disperses heat from inside the box), it is important not to block the back sides of the
control.
Overview:
Using screws, secure the Control unit mounting at a comfortable level on a
wall or vertical support, at least 3 feet above ground level. Minimize direct exposure to
rain, sunlight, water runoff, and lawn sprinkler systems. As with most electronics, avoid
placing the controls in tightly enclosed spaces to avoid a build-up of excess heat. For