15
system function.
All service should only be attempted by a person with appropriate electrical skills, with all
equipment disconnected from power.
The is shipped from the factory with a 240 VAC configuration. If 120VAC is needed, move
the internal jumpers as shown below. If unsure, seek professional advice.
This set of terminal screws can be located inside of the Control Unit, and accessed by
removing the four screws from the Control Unit's aluminum base. The factory voltage
setting is the 240V configuration, with a jumper clip inserted between the second and third
terminals. The Control Unit can be made to accept 110V by reconfiguring the jumper clips
as shown above left, with two jumper clips instead connecting the first and second
terminals, and the third and fourth terminals.