21
SAFETY n o ti c e :
Using the Power Button to turn the system OFF does not remove
power from the control box. Always disconnect power at the circuit breaker prior to
attempting any service procedure.
General Maintenance:
To maintain maximum performance, it is recommended that you remove and visually
inspect the cell at least every 3-4 months. The will remind you to do this at the appropriate
time by flashing the
“Check Cell” LED.
After you inspect the cell (and clean, if necessary) press and hold the System Status
button (next to the display) for 5 seconds to reset the flashing
“Check Cell” LED.
The Electrolytic Cell has a self-cleaning feature incorporated into the electronic
control’s
logic. In most cases, this self-cleaning action will keep the cell working at optimal efficiency
and help to inhibit mineral build-up. In areas with very hard water (high calcium and/or
mineral content), and in pools with poor water chemistry, the cell may require more
frequent cleaning (see below). If the
“Check Cell” LED remains on after a thorough
cleaning, it may require additional cleaning, or the cell may be at the end of its life cycle and
may require replacement.
See "Maintaining the Electrolytic Cell" for cleaning instructions.
Maintaining the Electrolytic Cell:
As a natural result of the electrolytic process which creates chlorine from salt
molecules, a white mineral build-up is attracted to the titanium plates in the Cell. The
self-cleaning feature helps to inhibit such build-up and scaling. However, the attraction of
minerals is inevitable, and eventually it must to be removed. The Control Unit will