-10-
Revision 5/F3534
©
Moffat Ltd, April 2005
Turbofan Convection Oven
Should changing of the cord be necessary, gain
access to the electrical connection terminal block
and strain relief by removing the back panel (four
screws).
WATER CONNECTION - US/CAN ONLY
A cold water supply should be fitted to the
water inlet (9mm /
3
/
8
” hose connection) which is
located on the rear of the left hand side of the
unit.
Connect water supply - Max inlet pressure 80psi /
550kPa.
Turn on water supply to check for leaks.
It is most important that the oven is installed
correctly and that the operation is correct
before use. Installation shall comply with local
electrical, health and safety requirements.
BEFORE CONNECTION TO THE POWER
SUPPLY
Unpack and check unit for damage and report
any damage to the carrier and dealer. Report
any deficiencies to your dealer. Fit the feet which
are packed inside the oven. Fit door handle to
oven door. Check that the available power
supply is correct to that shown on the rating plate
located on the right-hand side panel (refer figure
2.3).
208 V AC 60 Hz, 14.6 A, 3.2kW @ 208 V
220-240 V AC 60 Hz, 13.0 A, 3.1kW @ 240 V
208-220 V AC 50 Hz, 14.6 A, 3.2kW @ 220 V
230-240 V AC 50 Hz, 13.0 A, 3.1kW @ 240 V
LOCATION
To ensure correct ventilation for the motor and
controls the following minimum installation
clearances are to be adhered to:
Top
200mm / 8”
Rear
25mm / 1”
Left-hand side
25mm / 1”
Right-hand side
25mm / 1”
2. INSTALLATION
IMPORTANT:
THE OVEN VENT
LOCATED ON THE CABINET TOP MUST
NEVER BE OBSTRUCTED.
WARNING: THIS APPLIANCE MUST BE GROUNDED.
DOUBLE STACKING UNITS
When it is desired to mount one unit on top of
another the 31mm (1¼") high spacer feet must be
used. These short feet should be screwed on,
and the unit lifted on top of the bottom unit, where
it locates safely under its own weight, for normal
applications.
BEFORE USE
Operate the oven for about 1 hour at 200°C (400°
F) to remove any fumes or odours which may be
present.
ELECTRICAL CONNECTION
E311 convection ovens are supplied with
pre-fitted cords. Ensure unit is fitted with the
correct cord and plug for the installation (refer
specifications section).
IMPORTANT:
MAXIMUM INLET WATER
PRESSURE IS 550 kPa / 80 psi.
Figure 2.1
WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY
QUALIFIED PERSONS ONLY.
Position the oven in its allocated working
position. Use a spirit level to ensure the oven is
level from side to side and front to back. (If this is
not carried out, uneven cooking could occur).
The feet/legs used with bench or floor mounting
or provided with stands are adjustable and will
require adjusting in levelling the unit. It should be
positioned so the operating panel and oven
shelves are easily reachable for loading and
unloading.
L1
L2
Ground
Phase
Neutral
RED
BROWN
BLACK
GREEN/YELLOW
GREEN
WARNING:
THIS APPLIANCE MUST
BE GROUNDED / EARTHED
BLACK
BLUE
WHITE