![Blue Seal turbofan E311 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/blue-seal/turbofan-e311/turbofan-e311_service-manual_2776432036.webp)
-36-
Revision 5/F3534
©
Moffat Ltd, April 2005
Turbofan Convection Oven
Thermostat Shaft
Grill/Broil Switch
I M P O R T A N T :
I F T H E O V E N
TEMPERATURE NEEDS TO BE INCREASED,
ENSURE THAT THE THERMOSTAT IS IN THE
‘OFF’ POSITION BEFORE CARRYING OUT
ADJUSTMENT.
IF OVEN TEMPERATURE NEEDS TO BE
DECREASED, ENSURE THERMOSTAT IS IN
THE
‘MAX’
TEMPERATURE
POSITION
BEFORE CARRYING OUT ANY ADJUSTMENT.
1) Turn off power.
2) Remove thermostat knob by pulling it firmly
away from control panel.
3) Open control panel (refer 6.2.1). Remove two
screws on control panel holding thermostat.
4) The thermostat can now be removed.
Figure 6.4.2
Screws
Calibration Nut
Thermostat
Figure 6.4.1
6.4.1 THERMOSTAT CALIBRATION
6.4 ADJUSTMENT / CALIBRATION
6.3.27 INNER GLASS SEAL (E311MS)
1) Remove the door inner glass (refer 6.3.25).
2) The inner glass seal can now be removed and
replaced.
NOTE:
When fitting new seal, ensure join is at
top of door.