8
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
4.
Connect the gas supply to the appliance. A suitable joining compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
5.
Check gas operating pressure is as shown in the 'Specifications' section.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
7.
Check that the gas operating pressure is as shown in the 'Specifications' section.
NOTE: The operating pressure to be measured at the
manifold test point and with the burner operating at
the 'High Flame' setting.
8.
Turn off the mains gas supply and bleed the gas out of
the appliance gas lines.
9.
Turn ‘ON’ the gas supply and the appliance.
10. Verify the operating pressure remains correct.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE
CARRIED OUT BY AN QUALIFIED PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch
mounted adjacent to, but not behind the appliance. This switch must be clearly marked and readily
accessible in case of fire.
1.
Check that the electricity supply is correct as shown on the Rating Plate located on the front right
hand corner of the bottom sill.
2.
The electric fan motor and all corresponding electrical switches are connected through a 2m, 10Amp
flex located at the rear of the oven.
3.
For immediate electrical supply, simply fit a plug to the flex (if a plug is not already fitted) and plug
the lead into a properly earthed, 3 pin socket.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
'Operation' section of this manual.
•
Light the Target Top Pilot Burner.
•
Light the Target Top Main Burner.
•
Light the Oven Pilot and Main Burners.
•
Check the Oven Main Burner Thermostat operation.
•
Check the Low Fire Burner operation for Target Top and Oven.
•
Check the High Fire Burner operation for Target Top and Oven.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
recorded and kept with this manual.
(These details can be found on the Rating Plate rating plate located on the front right
hand corner of the bottom sill. Refer to the 'Gas Connection' section)
.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Installation
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Fig 1
Low Fire
Adjustment
Screw
Manifold
Pressure Test
Point
Содержание G576
Страница 6: ...4 Dimensions G576 Electrical Connection Point Gas Connection Point ...
Страница 26: ...24 ...