3
Specifications
Model Numbers Covered in this Specification
G576
Gas Target Top Range Convection Oven .
General
A commercial heavy duty, general purpose fully modular, gas fired Target Top Range Convection
Oven, having a high output, two stage double-ring iron cast burner offering accurate temperature
control and infinitely variable heat with the heat radiating out from the centre of the Target Top.
The Main Burner is located underneath removable cast target top plates.
The Target Top is uses a 45Mj/hr burner and as standard is fitted with full pilot, flame failure
protection.
The Oven utilizes a 30Mj/hr oven main burner with pilot and flame failure protection and is fitted
with piezo ignition to the oven pilot burner. The Oven is fitted with a 100watt heavy duty motor with
200 mm diameter heavy duty circulation fan.
The oven is controlled with a 50 to 320ºC thermostat. Indicator lights for power and heating.
Burner automatically cuts-off when oven door is opened. Access to the oven main and pilot burner is
via a drop down door and a removable front lintel on the lower part of the oven.
The appliance is built to facilitate easy cleaning and maintenance with all parts being front accessible
once the appliance is installed.
Gas Supply Requirements
NOTE:
•
(*) The burner operating pressure is to be measured at the manifold test point with the
main burner operating at the 'High Flame' setting.
•
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
•
TOWN GAS Only - The burner operating pressure is to be adjusted using the adjustable
gas regulator supplied.
•
(**) Town Gas Option is only available with specific ex-factory built Town Gas models,
which can also be converted to any other gas. Standard models can only be converted
between Nat. Gas, LP Gas and Butane, but not Town Gas.
•
Refer to the ‘Gas Conversion and Specifications' section of this manual for further
details.
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the
right hand side, 32 mm from the rear and 655 mm from the floor and is reached from beneath the
appliance. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
230-240 V a.c, 50 Hz, 1.6 A, 1P+N+E.
0.4 kW
Oven Fan Motor - 100 W.
Natural Gas
LP Gas / Butane
Town Gas (**)
Target Top
Oven
Target Top
Oven
Target Top
Oven
Input Rate
(N.H.G.C.)
45 MJ/hr
(42,650 Btu/hr)
30 MJ/hr
(28,435 Btu/hr)
45 MJ/hr
(42,650 Btu/hr)
30 MJ/hr
(28,435 Btu/hr)
45 MJ/hr
(42,650 Btu/hr)
30 MJ/hr
(28,435 Btu/hr)
Gas Supply
Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Burner Operating
Pressure
0.95 kPa (*)
(3.7” w.c.)
2.60 kPa (*)
(10.0” w.c.)
Gas Connection
3
/
4
” B.S.P. Male
0.63 kPa (*)
(2.5” w.c.)
Содержание G576
Страница 6: ...4 Dimensions G576 Electrical Connection Point Gas Connection Point ...
Страница 26: ...24 ...