20
Gas Type Identification Label
On completion of the gas conversion, replace gas type identification label, located:-
- At the rear of the unit, above the gas connection.
- Beside the Rating Plate.
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the
'Operation' section of this manual.
•
Light the Target Top Pilot Burner.
•
Light the Target Top Main Burner.
•
Check the Low Fire burner operation for Target Top and Oven.
•
Check the High Fire burner operation for Target Top and Oven.
•
Check the Oven Main Burner Thermostat operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correct.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Gas Conversion and Specifications
Содержание G576
Страница 6: ...4 Dimensions G576 Electrical Connection Point Gas Connection Point ...
Страница 26: ...24 ...