11
Operation
Oven ‘Shut-Down’
1.
To ‘Shut Down’ the oven, turn the oven thermostat to the ‘0’ position, the oven main burners will go
out.
2.
Turn the gas control valve to the 'OFF' position and this will extinguish the pilot burner. (To relight
the pilot burner, refer to ‘Oven Pilot Ignition’ above).
3.
Turn ‘OFF’ the electrical power at the mains supply, the (white) power indicator light will extinguish.
NOTE: If the main burner has recently been turned 'OFF', should you wish to re-light the oven, the
interlock will not allow the gas valve to be turned to the main burner position until the
interlock has reset (Approximately 1 minute). DO NOT FORCE THE GAS VALVE TO THE
MAIN BURNER POSITION UNTIL THE INTERLOCK HAS RESET, as this will damage the gas
control valve.
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal operation,
be noticed, the appliance requires IMMEDIATE service by a qualified service person and shall not
be used until such service is carried out.
IMPORTANT