M380 Owner’s Manual___________________________________Interior and Exterior Systems Operation - Inverter – 4-5
Rev. “F” 4-5-3
NOTE: The default Generator Start selection is Manual (Push On). This setting disables all
automatic start functions. Any other selection from the Generator Start menu, enables the
RC7GS to automatically start the generator based upon the battery’s state-of-charge.
4-5.1.4.4 Generator Stop
The RC7GS can be configured to shut down the generator automatically when the batteries reach 90
to 99% SOC, or when the charger initiates the Absorption or the Float mode of charging. Refer to the
inverter/charger’s Operators manual for a detailed description on charging modes. The default is
Manual (Push Off).
The generator can be stopped at any time by accessing the user menu until the “Gen Start/Stop:
Press (On/Off)” menu is displayed. Press the ON/OFF push button on the RC7GS front panel until the
generator stops.
NOTE: The generator will start immediately if the auto-start parameters are still met.
The generator can be started or stopped at any time by pressing the DOWN arrow push button (User
Menu) until the Gen Start/Stop menu is displayed. Press and hold the On/Off push button on the
RC7GS front panel until the generator starts or stops. Release the push button as soon as the
generator starts. If the inverter/charger senses an ac supply while the remote control On/Off push
button is pressed, it will shut down the generator.
NOTE: If the genset is manually started from the remote, a manual override is initiated and the
generator will NOT stop automatically. Shut down the generator manually.
4-5.1.4.5 Begin Gen Quiet and End Gen Quiet
The period of time during which the generator is prevented from starting automatically can be defined
using the RC7GS.
To specify the begin quiet time, scroll to the Begin Gen Quiet: 00:00 by using the UP and DOWN
arrow push buttons. Set the Begin Gen Quiet start time. The selected digit for hours or minutes will be
underlined and highlighted (
refer to 4-5.1.4.1 Set Clock section
for details on setting the time).
Press the DOWN arrow to access the End Gen Quiet 00:00 menu and select the appropriate end
time.
NOTE: Setting begin and end time to 00:00 defeats the quiet time mode.
NOTE: If the generator is running at the begin quiet time, it will be shut down automatically. If
the auto-start parameters are met during quiet time, the buzzer will sound and the LCD
displays the message “Gen Quiet Fault.” The generator will start automatically at the end of
the quiet time.
4-5.1.4.6 Saving Setup Choices
Once the setup options are complete, press and hold both the UP and DOWN arrow push buttons
until the display clears (approximately 5 seconds). The setup choices will be saved in nonvolatile
memory 20 seconds after exiting the Setup menu. If no other actions are taken. These settings will be
preserved until changed.
NOTE: The GenStart settings will not be saved if the RC7GS is disconnected or dc power is
lost.
IMPORTANT NOTE: If Auto Gen Start is enabled the generator cannot be started from
any remote starts in coach. Generator can be started by disabling Auto Gen Start or
by manually starting from the RC7GS Remote Panel.
Содержание M380 2003
Страница 1: ...Rev F...
Страница 100: ...2 2 Instruments and Controls Driver and Co Pilots Area________________________________M380 Owner s Manual 2 2 28 Rev F...
Страница 375: ...DIRECTV HD RECEIVER USER GUIDE...
Страница 377: ...Section Title...
Страница 379: ...Section Title 1 2 Welcome 3 About Your User Guide 4 Defining High Definition Chapter 1...
Страница 417: ...Section Title Chapter 3 39 40 Watching TV 43 The Guide 45 Autotune 47 Pay Per View Chapter 3...
Страница 426: ......
Страница 473: ......
Страница 476: ......