Installation
12
Deliming System Connection and Priming (BCXĆ14 units only)
DELIMING SYSTEM CONNECTION
1. Push deliming tube onto barbed fitting on
oven back.
Figure 6
2. Cut deliming tube to length using the bottom
of the deliming fluid reservoir in its mounted
position as a guide. Install the jug weight on
the deliming fluid reservoir end of the deliming
tube.
Figure 7
3. Insert the end of the deliming tube with the jug
weight into the deliming solution reservoir.
Figure 8
NOTE: If needed use supplied hose retainers and
self drilling screws to route the deliming
tube away from hot exhaust ports.
PRIME THE DELIMING PUMP
To prime the delime pump, use the following proĆ
cedure for your oven control.
Standard Control
1. Rotate the mode switch to COOL DOWN.
2. Press and hold both the Timer knob and the
Steam on Demand knob simultaneously. This
will turn the pump on.
3. Watch for deliming solution to flow through the
tube. Release the two knobs once the delime
solution has reached the barbed fitting on the
back of the oven.
4. Once the pump is primed, you may turn the
mode switch to any position.