OM-APEX E V1.06
November 19, 2012
Page 26
APEX CBT
AIR SETTINGS
Th
e high output (when there is a heat demand) is set in the factory and can not be adjusted. Th
e low output
(standby) can be adjusted with the screw on the primary air blade (see fi g 25) situated behind the draft box
underneath the loading door. It controls the gap A. Th
e bigger the gap, the more combustion air enters into the
fi rebox, the higher the low burn.
Every installation is diff erent because of draft , kind of wood being used and geographic location.
Adjust the fl ap in a way that it maintains a fi re overnight on standby but not using high amounts of wood.
Fig. 25 Low output adjustment
THERMOSTATS
If your furnace is operating as a combination unit remember both units will not fi re at the same time. If the
wood furnace is to be your main source of heat, set the wood thermostat at your desired room temperature and
set the thermostat from your alternate furnace approximately 5° F (3°C) lower.
Note:
If the alternative furnace is running and the wood furnace is starting to heat up aft er (re-)loading, the
alternate furnace will shut off automatically.
When programmable thermostats are used, it is recommended that the wood thermostat is programmed so the
Apex will fi re up before the alternate furnace will. Th
is will give the Apex time to build up a hot fi re again aft er
being in standby mode.
OPERATING INSTRUCTIONS cont.
A
Содержание APEX CBT
Страница 5: ...OM APEX E V1 06 November 19 2012 Page 5 APEX CBT APPLIANCE DIMENSIONS ...
Страница 7: ...OM APEX E V1 06 November 19 2012 Page 7 APEX CBT CERTIFICATION LABEL ...
Страница 33: ...OM APEX E V1 06 November 19 2012 Page 33 APEX CBT BRICK LAYOUT ...
Страница 40: ...OM APEX E V1 06 November 19 2012 Page 40 APEX CBT NOTES ...