INSTALLATION INSTRUCTIONS cont.
Apex CBT as independent furnace:
When the blower is installed on the left side of the Apex CBT, the bypass handle needs to be moved to the right
side (see “INSTALLATION INSTRUCTIONS cont.” on page 14), so if possible, install the blower on the right
side.
Install the blower more to the front of the unit as that is where most of the heat is. When using the VB1000
blower cut an opening 13 1/4” W x 11 13/16” H in the side panel about 9” from the front (Distance A, see fi g.
4 ). Check the height of the hole with the blower. Th
e side panel can be taken off , it might be easier to cut the
opening that way. Use the pre-punched cutouts if applicable.
A
W
H
Fig. 4
Fig. 5
Metal strip
Casing
Insulation
DO NOT USE INTERCONNECT DUCT ELBOWS THAT HAVE AN INSIDE RADIUS OF LESS THAN
6” (150mm.). THE WARM-AIR SUPPLY OF THE APEX FURNACE SHALL NOT BE CONNECTED
TO THE COLD-AIR RETURN INLET OF THE EXISTING OR ALTERNATE FURNACE. THE
POSSIBILITY EXISTS THAT THE COMPONENTS OF THE EXISTING OR ALTERNATE FURNACE
MAY OVERHEAT, CAUSING THE CENTRAL FURNACE TO OPERATE OTHER THAN INTENDED.
COMBUSTION AIR
Insure adequate combustion air allowing for all other exhausting type appliances in the dwelling (range hoods,
dryers, etc). In airtight houses it is recommended to install a fresh air inlet into the basement room where the
furnace is located. Recommended intake size is 1.5 sq in
2
per 1000 BTU’s.
Содержание APEX CBT
Страница 5: ...OM APEX E V1 06 November 19 2012 Page 5 APEX CBT APPLIANCE DIMENSIONS ...
Страница 7: ...OM APEX E V1 06 November 19 2012 Page 7 APEX CBT CERTIFICATION LABEL ...
Страница 33: ...OM APEX E V1 06 November 19 2012 Page 33 APEX CBT BRICK LAYOUT ...
Страница 40: ...OM APEX E V1 06 November 19 2012 Page 40 APEX CBT NOTES ...