Connecting to a network
Setting the IP Address for Ultimatte 12
Your Ultimatte 12 main unit is shipped with a default IP address of 192.168.10.220 but you can
change this address if you want to connect to a network. This is also important when sharing
multiple Ultimatte units on your network and controlling them using a single Smart Remote 4.
To change the IP address for an Ultimatte main unit, you will first need to download and install
the latest Blackmagic Ultimatte Setup software from the Blackmagic Design support center at
www.blackmagicdesign.com/support. For installation information refer to the ‘updating the
internal software’ section in this manual.
After installation:
1
Connect the desired Ultimatte 12 main unit to your computer via USB.
2
Launch Blackmagic Ultimatte Setup.
3
Click on the unit icon for your Ultimatte to open the setup settings.
4
In the ‘configure’ tab, enter the IP address, subnet mask and gateway settings.
5
Click ‘save’ to confirm the settings.
Repeat the same process for each main unit you want to control. The subnet mask and gateway
should match your network settings and stay the same between all units, but make sure each
unit has its own unique IP address.
Setting the IP Address for your Smart Remote 4
Now that each Ultimatte main unit has a new IP address, you will need to configure the IP
address of your Smart Remote 4 so you can control the main units on your network.
To set the IP address on your Smart Remote 4:
1
Reveal the Windows desktop by tapping on the info icon in the Smart Remote
touchscreen information and file control section. Now tap on the ‘options’ settings and
tap exit to desktop.
2
Navigate to the Windows network settings.
3
In the Ethernet related settings, select ‘change adapter options’.
4
Double tap on the ‘Ultimatte’ network to open the Ultimatte status window.
5
Tap on ‘properties’.
6
In the properties window, double tap on ‘internet protocol version 4 (TCP/IPv4) to open
its setting properties.
7
Select the ‘obtain an IP address automatically’ setting to let your Smart Remote find its
own IP address to join the network you are connected to. Or if you want to enter the
IP address, subnet mask and default gateway settings, select ‘use the following
IP address’ and set it manually.
8
Tap ‘OK’ to confirm the settings.
Double tap on the SR4 smart remote software icon to return to the touchscreen control panel.
18
Connecting to a network
Содержание Smart Remote 4
Страница 67: ...オペレーションマニュアル 2017年11月 日本語 Ultimatte 12 ...
Страница 132: ...Manuel d utilisation Novembre 2017 Français Ultimatte 12 ...
Страница 197: ...Benutzerhandbuch November 2017 Ultimatte 12 Deutsch ...
Страница 262: ...Manual de instrucciones Noviembre 2017 Español Ultimatte 12 ...
Страница 327: ...操作手册 2017年11月 中文 Ultimatte 12 ...
Страница 392: ...Руководство по эксплуатации Ноябрь 2017 г Ultimatte 12 Русский ...
Страница 457: ...Manual de Operações Novembro 2017 Português Ultimatte 12 ...