GPIO MENU
The GPI inputs allow external devices to trigger saved setup files in each input in a pre-
determined order. The maximum number of events is defined by the number of GPI inputs,
therefore the number of events you can use is 5.
It is also possible for the main unit to trigger events in other devices using the GPI output. This
triggering can be done manually, or upon loading a file if the GPI output was saved as part of
that file.
CONTROL KNOBS
GPI OUT Delay Frames
This control sets the delay, in number of frames, between triggering the event and the
execution of the GPI output switch closure. The maximum delay is 120 Frames.
GPI Functions Buttons
GPI Output Save
In order to initiate a GPI output upon loading a file, the appropriate instructions must be
saved as part of that file. When ‘GPI out save’ is selected, the instructions to trigger a
GPI output will become part of the current workspace settings. When the current
workspace settings are saved as a setup file, the instructions to trigger the GPI output
are saved with this file.
When the saved file, which includes the triggering instructions, is loaded into the
current workspace, the triggering instructions will initiate the proper GPI
output sequence.
GPI Out Low/High
Pressing this button toggles the GPI output state between low and high.
GPI Out
This provides a programmable state output, whose width and level are dependent on
the GPI out low/high setting and GPI out delay adjustment.
GPI Setup Menu
From the GPI setup menu, you can choose GPI files from the list of previously saved setup files
and load them into each GPI input. You can can step through each file to verify that the selected
files were the correct ones, and that the sequence by which these files were listed was correct.
If needed, you can edit each GPI list by removing, adding, or inserting any number of files.
GPI 1 to 5
These windows allows the user to set up the files in the order by which they will be
loaded when triggered by the signal connected to each respective GPI input.
Add
With each press, this button will add the highlighted file in the files list to the selected
GPI events list.
Remove
Press this button to remove a highlighted file from the selected GPI events list.
Remove All
This button will remove all the files from the selected GPI events list.
Step
Press this button to move down through the highlighted file selection and automatically
load the selected file into the current work space. Any file on the GPI events list can
be highlighted and loaded in the current work space by touching the corresponding
file name.
38
38
38
Changing Settings
Содержание Smart Remote 4
Страница 67: ...オペレーションマニュアル 2017年11月 日本語 Ultimatte 12 ...
Страница 132: ...Manuel d utilisation Novembre 2017 Français Ultimatte 12 ...
Страница 197: ...Benutzerhandbuch November 2017 Ultimatte 12 Deutsch ...
Страница 262: ...Manual de instrucciones Noviembre 2017 Español Ultimatte 12 ...
Страница 327: ...操作手册 2017年11月 中文 Ultimatte 12 ...
Страница 392: ...Руководство по эксплуатации Ноябрь 2017 г Ultimatte 12 Русский ...
Страница 457: ...Manual de Operações Novembro 2017 Português Ultimatte 12 ...