![Black Box Terminal Eliminator Plus Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/black-box/terminal-eliminator-plus/terminal-eliminator-plus_manual_2764214036.webp)
37
CHAPTER 5: Operation
5.2.5 “B
ROADCAST
”
To enter Broadcast Mode from either of the Concentrate modes, the user
sends from the master device the two ASCII characters “BC” followed by a
carriage-return character (ASCII [CR]).
5.2.6 “I
NITIALIZATION
”
To access the initialization menu (from which you can change some of the
TEP’s settings) from either of the Concentrate modes, the user sends from
the master device the four ASCII characters “INIT” followed by a carriage-
return character (ASCII [CR]).
5.2.7 “R
ESET
”
To reset the TEP and clear all its buffers from either of the Concentrate
modes, the user sends from the master device the five ASCII characters
“RESET” followed by a carriage-return character (ASCII [CR]).
5.2.8 “B
REAK
”
To send a 250-ms break sequence to a slave device when the TEP is in one
of the Conversation modes, the user sends from the master device the four
ASCII characters “BBBB” followed by a carriage-return character (ASCII
[CR]). If the current mode is one of the Concentrate modes, include an
ASCII port number after the four “B”s to indicate which slave device should
receive the break sequence (for example, “BBBB1[CR]” to send a break to
the slave device on port 1).
5.2.9 C
HAINED
C
OMMANDS
It is possible to go from either (a) a Conversation mode with one slave device
to a Conversation mode with another slave device or (b) a Conversation mode
to Broadcast Only Mode, or vice versa, without an interlude of the standard
Concentrate mode. (See
Section 5.3
for more information about these
modes.) This can be done by chaining multiple commands together while
output flow control is disabled at the master port.
For example, if you are using X-ON/X-OFF flow control on the master port
and you want to switch from Conversation mode with slave port 1 to
Conversation mode with slave port 2, enter the following chained command
string with imbedded software flow-control codes: [X-OFF] NNNNC2
[X-ON]. The X-OFF will prevent concentrated slave data from being sent