CHAPTER 4: CONFIGURATION
4.4.3 ACCESS
The access configuration is set in this menu.
You have the following options to access the menu.
OSD
You can select the following settings.
TABLE 4-15. ACCESS SETTINGS
FIELD
SELECTION
DESCRIPTION
Force User Login
activated
The user has to login with a user name and a password once to enter the OSD.
The user remains logged in until he explicitly logs out or an auto logout occurs.
NOTE: When using the Force User Login function, console favorites and console
macros still remain active.
deactivated
Function not active (default)
Enable User ACL
activated
CPU access is restricted according to the permissions in the ACL (Access Control List).
User login is required.
Switching by keyboard Hotkeys requires a prior login.
deactivated
Function not active (default)
Enable Console ACL
activated
CPU access is restricted according to the permissions in the respective Console ACL
(Access Control List). No login required.
deactivated
Function not active
Enable new User
activated
Newly created users automatically receive access to all CPUs
deactivated
Function not active (default)
Enable new CON
activated
Newly created CON Devices automatically receive access to all CPUs
deactivated
Function not active (default)
Auto Disconnect
activated
Upon opening the OSD, the console will be automatically disconnected
from the current CPU.
deactivated
Function not active (default)
OSD Timeout
0-999 seconds
Period of inactivity after which OSD will be closed automatically.
Select 0 seconds for no timeout
(default: 0 seconds)
Auto Logout
0-999 minutes
Period of inactivity of a logged-in user at a console after which he will be automatically
logged out. There may be a disconnect because of the logout, depending on the
defined rights in each CON and user ACL.
Select 0 minutes for an automatic user logout when leaving OSD.
Using the setting -1 allows the user to be logged in permanently, until a manual
logout is executed.
The timer is not active as long as the OSD is open
(default: 0 minutes)