73
1.877.877.2269
BLACKBOX.COM
NEED HELP?
LEAVE THE TECH TO US
LIVE 24/7
TECHNICAL
SUPPORT
1.877.877.2269
CHAPTER 4: CONFIGURATION
TABLE 4-11 (CONTINUED). SYSTEM DATA SETTINGS
FIELD
SELECTION
DESCRIPTION
Enable COM Echo
activated
Send all switching commands performed in the matrix as an echo via serial interface.
NOTE: This function should be enabled when using a media control via serial interface.
deactivated
Function not active (default)
Enable LAN Echo
activated
Send all switching commands performed in the matrix as an echo via LAN connection.
NOTE: This function should be enabled when using a media control via LAN
connection or when using stacking with two ore more matrices.
deactivated
Function not active (default)
Enable Redundancy
activated
Automatically switch to the second link of a connected redundant CON Unit
when losing the primary link of a CPU Unit (default).
NOTE: This function will have to be activated for both matrices in a fully redundant
setup.
deactivated
Function not active
Synchronize
activated
Synchronize the slave matrix to the switch status of the master matrix.
deactivated
Function not active (default)
Echo Only
activated
Synchronize the matrix according to the echo of a second matrix.
NOTE: This is a bidirectional synchronization where both matrices have to be
configured as Synchronize with the Master IP of the respective other matrix.
deactivated
Function not active (default)
Master IP Address
Numerical value
Set the network address of the master matrix (default value: 000.000.000.000)
Invalid IO-Boards
activated
Keep I/O boards with incorrect or invalid firmware online in the matrix.
NOTE: To keep an I/O board with wrong or damaged firmware online in the matrix,
the maintenance mode of the matrix will be activated.
deactivated
Shut down I/O boards with incorrect or invalid firmware automatically (default).
Hor. Mouse Speed 1/x
1–9
Adjustment of the horizontal mouse speed, 1 = slow, 9 = fast (default value: 4)
Ver. Mouse Speed 1/x
1–9
Adjustment of the vertical mouse speed, 1 = slow, 9 = fast (default value: 5)
Double Click Time
100–800
Adjustment of the time slot for a double-click (default value: 200 ms)
Keyboard layout
Region
Set the OSD keyboard layout according to the keyboard used (default: German (DE))