Common Command Introduction
8
failures are identified by a unique binary code in the returned <status> number. A “0” response
indicates that no failures occurred.
Query Format
*TST?
Query Response
*TST <status>
<status> = 0 self-test successful
Example
The following causes a self-test to be performed:
TST?
Return(if no failure):
*TST 0
Related Commands
*CAL
2.10 WAI
Description
The *WAI (WAIT to continue) command, requires by the IEEE 488.2 standard, has no effect on
the instrument, as the signal generator only starts processing a command when the previous com-
mand has been entirely executed.
Command Syntax
*WAI
Related Commands
*OPC
2.11 Comm_Header Command
Description
This command is used to change the query command returned format. “SHORT” parameter re-
turns short format. “LONG” parameter returns long format. “OFF” returns nothing.
Command Syntax
Comm_HeaDeR <parameter>
<parameter>={SHORT,LONG,OFF}
Query Format
Comm_HeaDeR?
Query Response
chdr <parameter>
Example
Set query command format to long. CHDR LONG Read query command format.
CHDR?
Return:
COMM_HEADER LONG
2.12 Output Command
Description
Enable or disable the output of the [Output] connector at the front panel corresponding to the
channel. The query returns “ON” or “OFF” and “LOAD”, “PLRT” parameters.
Command Syntax
<channel>:OUTPut <parameter>
<channel>={C1, C2}
<parameter >={a parameter from the table below}
< load>={please see the note below.}
Parameters Value
Description
ON
—
Turn on
OFF
—
Turn off
LOAD
<load>
value of load(defaultunite is ohm)
PLRT
<NOR,INVT> value of polarity parameter