Preliminary
Trigger
The Karbon
KBN-7-2
BitFlow, Inc.
Version F.0
7.2 Trigger
7.2.1 Trigger Input Types
There are four trigger inputs.
TRIGGER_TTL - Single ended TTL level trigger
TRIGGER_DIFF - Differential (LVDS) trigger
TRIGGER_OPTO - Optocoupled trigger
FEN - The FEN signal on the CL1 connector.
The hardware trigger is enabled/disabled by the bit EN_TRIGGER. Only one input at a
time is active (the software trigger bit, SW_TRIG, is always active). The active trigger is
selected by the bitfield SEL_TRIG. The current level of these inputs can be read from
software by reading the bits RD_TRIG_DIFF, RD_TRIG_TTL, RD_TRIG_OPTO and RD_
FEN. The unselected triggers will have no effect on the board. However, they can be
used as general purpose inputs.
7.2.2 The Optocoupled Trigger
The opto-coupled trigger allows the acquisition circuitry to accept a trigger signal
without having a galvanic connection to the trigger source. This is mandatory in some
medical and industrial application. The trigger information is passed as a light pulse
from an on-board LED that is coupled to a receiving phototransistor. The LED and the
phototransistor are in the same package, a Sharp PC3H711. Figure 7-1 shows the
electrical diagram of the optocoupled trigger circuit and a suggested circuit for the
driver. The LED is driven by an open collector driver. The user must supply his +5V
power to the LED. Note that there is no galvanic connection between the user’s circuit
and the acquisition circuitry.
Содержание KBN-CL4-2.51-SP
Страница 20: ...P r e l i m i n a r y The Karbon CL Models The Karbon KBN 1 12 BitFlow Inc Version F 0 ...
Страница 62: ...P r e l i m i n a r y DEST_ADD The Karbon KBN 3 8 BitFlow Inc Version F 0 ...
Страница 190: ...P r e l i m i n a r y Camera Link Controls CCs The Karbon KBN 7 12 BitFlow Inc Version F 0 ...
Страница 194: ...P r e l i m i n a r y Power Consumption The Karbon KBN 8 4 BitFlow Inc Version F 0 8 4 Power Consumption ...