![BitFlow KBN-CL4-2.51-SP Скачать руководство пользователя страница 129](http://html.mh-extra.com/html/bitflow/kbn-cl4-2-51-sp/kbn-cl4-2-51-sp_hardware-reference-manual_2758657129.webp)
Preliminary
Camera Control Registers
CON18 Register
Version F.0
BitFlow, Inc.
KBN-4-67
ALPF
R/W, CON18[16..0], Karbon, Neon, R64
This register defines the Active Lines Per Frame of the vertical acquisition window.
Let’s assume for example a single tap camera with 2K lines per frame. If we want to
acquire 400 lines per frame, the ALPF will be programmed to 400. For a 2-tap odd-
even lines camera, with 2K lines per frame, to acquire 400 pixels the ALPF will be pro-
grammed with the value 200, as for every LEN the camera supplies two lines.
TOP_REV
RO, CON9[11..0], Karbon, Neon, R64
Firmware revision.
SIG_GEN_POL
R/W, CON18[30], Karbon, Neon, R64
This bit allows for the inversion of the free running generator’s output.
SCALE_BY8K
R/W, CON18[31], Karbon, Neon, R64
Scaling down the clock to the free running generator can yield waveforms on the
order of single Hz.
SIG_GEN_POL Meaning
0
Free running generator supplies signal as is
1
Invert output of the free running signal generator.
SCALE_BY8K Meaning
0
Use on board CLOCK as is for the free running signal
generator
1
Divide by 8K the on-board CLOCK to be used by the
free running generator..
Содержание KBN-CL4-2.51-SP
Страница 20: ...P r e l i m i n a r y The Karbon CL Models The Karbon KBN 1 12 BitFlow Inc Version F 0 ...
Страница 62: ...P r e l i m i n a r y DEST_ADD The Karbon KBN 3 8 BitFlow Inc Version F 0 ...
Страница 190: ...P r e l i m i n a r y Camera Link Controls CCs The Karbon KBN 7 12 BitFlow Inc Version F 0 ...
Страница 194: ...P r e l i m i n a r y Power Consumption The Karbon KBN 8 4 BitFlow Inc Version F 0 8 4 Power Consumption ...