RS-232 Interface
33
Baud Select
(Bx)
Function
Selects a baud rate list ed in F igu r e 27.
Remarks
When the meter recognizes a valid Bx command, its baud rate is immediately
changed. (The controller is assumed to be transmitting at the new rate; other-
wise sending commands would not be possible.)
This command overrides the DIP switch setting.
Xmission Flow Control
(XO/XF)
Function
Enables or disables the XON/XOFF flow control.
XO enables flow control.
XF disables flow control.
Remarks
When data is being sent from the power meter to the computer and flow con-
trol is enabled, data transmission will be suspended when the XOFF character
(hexadecimal 13) is sent by the computer. Transmission will resume when
XON (hex 11) is sent by the computer.
When data is being sent from the computer to the power meter, XOFF will be
sent to the computer when the input buffer fills up. XON will be sent to the
computer when the buffer has emptied.
Figure 27
Baud Rates
Command
Baud Rate
B2
300
B3
600
B4
1200
B5
2400
B6
4800
B7
9600