background image

 

biozoom copyright© 2021 

 

 

3

 

 

 

1

 

How to get started 

 

Please read the chapters of this manual in the ranked order carefully to correctly learn the handling of the 
device.  
 
Before you can make a measurement, you must download the 

V I T A L I T Y  C H E C K   

app onto your phone 

or tablet (chapter 5) and you must charge the battery of your device (chapter 8). With a too low charging 
level, it is impossible to activate the device successfully.  
 
The chapter 10 describes all necessary steps to do measurement. This includes preparations, for example 
how to connect the scanner with your phone/tablet. Before you conduct your first measurement please 
read the general instruction for a successful and precise measurement in chapter 11. 
 
When the scanner is switched on, the light of the status indicators always informs you about the present 
status. If the indication is not identical with the descriptions in chapter 10, please go to the chapter 12 
and check the information on the indicated status. As an automatic timeout will switch the scanner off in 
some situations, please memorize the configuration of lighting before searching in the chapter 12.  
 

 
 

2

 

Safety

 

 

Read  the  safety  instructions  carefully  before  using  the 

V I T A L I T Y   C H E C K

.  Retain these 

instructions for future use. 

 

Only use the scanner as described in the manual. 

 

Do not stare into the lights the device uses to measure. Keep your hand on the sensor during 
the  complete  measurement.  Staring  into  the  active  lights  can  cause  permanent  or  non-
permanent damage to your eyes. 

 

Do not use the device near water or spill liquid of any kind on the device as this may cause a 
short circuit, a fire, or an electric shock which could cause serious injury, death, and property 
loss. 

 

Do not use or store the device in extreme temperatures (for example, do not leave it in a car 
that is in direct sunlight). The device might overheat and may present a burn and fire risk and 
cease to function. 

 

Do not drop the device or allow objects to fall on as this might cause a damage to the battery 
which might cause an explosion resulting in serious injury, death, and property loss. 

 

Do not dispose of the device in fire as this might cause an explosion resulting in serious injury, 
death, and property loss. 

 

Do  not  use  the  device  in an  aircraft  as  Federal  Aviation  Ad-  ministration  (FAA)  and  Federal 
Communications Commission (FCC) regulations prohibit the use of wireless devices while in the 
air. Turn off the device before boarding an aircraft. Using the device on an aircraft might affect 
aircraft instrumentation, communication, and performance; might disrupt the network; might 
otherwise be dangerous to the operation of the aircraft, its crew, and its passengers; and might 
be illegal. 

 

Do not disassemble the device. 

 

Most  modern  electronic  equipment  is  shielded  from  radio  frequency (RF)  signals.  However, 
certain electronic equipment might not be shielded against the RF signals from the device. Keep 
the device away from medical devices, including pacemakers and hearing aids, as they might 
malfunction and cause serious injury or death to the user and others. 

Содержание VITALITY CHECK MSRRS SCN05

Страница 1: ...User Manual...

Страница 2: ...TURNING THE DEVICE ON AND OFF 8 10 STEPS FOR PERFORMING A MEASUREMENT 9 10 1 HOW TO CONNECT SCANNER WITH PHONE TABLET 9 10 2 PERFORMING MEASUREMENTS 12 11 MEASUREMENT BASICS 16 PREPARATION BEFORE STAR...

Страница 3: ...he active lights can cause permanent or non permanent damage to your eyes Do not use the device near water or spill liquid of any kind on the device as this may cause a short circuit a fire or an elec...

Страница 4: ...0 C Do not cover the device or charger while charging CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Disposal Do not disp...

Страница 5: ...e apps details id net biozoom vitalitycheck2020 IOS https apps apple com de app biozoom vitality check id1552854204 6 Package content VITALITY CHECK scanner Quick Start Guide 7 Product Description The...

Страница 6: ...ymbols will switch on one after the other until all symbols lit When the measurement is finished the light will be switched off More details please see chapter 12 The WIFI indicator 6 light up in gree...

Страница 7: ...tched off Attention Please charge the VITALITY CHECK scanner before its first use 1 Plug the USB CTM cable into the charging port 2 Connect the cable to a USB charger or USB port 3 Switch the scanner...

Страница 8: ...ablet The complete procedure how to connect the scanner with your phone tablet is described in chapter 10 1 If you switch the scanner ON and you have made measurements already the status indicator wil...

Страница 9: ...measurements without going through the connection procedure again If you always use the same scanner you only need to open the app switch on the scanner and press the NUTRITION button in the app The c...

Страница 10: ...on enables Permission to scan Identification by status connection with phone QR code typing serial number Press ALLOW Drop down menu to select language Push this button at your scanner to switch the s...

Страница 11: ...eft corner of the VITALITY CHECK app to select and start the Setup wizard manually Figure 5 Follow the instructions to connect the additional scanner now with the phone tablet The Setup wizard guides...

Страница 12: ...nd phone tablet via the WIFI of the scanner Figure 6 One important difference between FULL and LIGHT measurement is the number of measurements you need to take FULL includes four measurements LIGHT on...

Страница 13: ...ns off Only the status indicator still lights in blue Figure 8 Figure 8 Your phone tablet will connect to an existing WIFI or alternatively use a cellular connection to the internet After successful c...

Страница 14: ...nt directly after the measurement is done In many situations the server will notice if you have not placed the hand on the sensor properly and you will get a message with recommendations Following the...

Страница 15: ...that the change of Wifi connection is tolerated by the user The drawback of this configuration is that the user is not informed right away if the placement of the hand was incorrect and incorrect sing...

Страница 16: ...have a small effect on the measurement so it is better to wait 30 minutes after washing hands to get the most precise results Measure on unhurt healthy untreated bare and dry skin only to get consiste...

Страница 17: ...Figure 14 Figure 14 Do not move your hand or shift weight during measurement It is important to hold your hand still during the measurement The scanner does a set of different measurements and compar...

Страница 18: ...d vegetable They are an excellent marker for the quality of your nutrition and your antioxidant level Everything you eat and drink including normal food drinks and nutritional supplements influence yo...

Страница 19: ...er the antioxidant value temporarily Be aware that there are several other effects which can influence the nutrition substances measured by the scanner 12 Troubleshooting Below you find a table summar...

Страница 20: ...er s firmware is prior to 2021 Scanner is switched on status indicator lights orange and WIFI indicator lights green or is blinking green Follow the instructions of the setup wizard of the app when co...

Страница 21: ...cator will flickering Do not move your hand now 8 Scanner has finished the measurement The measurement has been finished 9 blinking Scanner has finished the measurement Scanner requests you to take yo...

Страница 22: ...thumb thenar Use only as specified in this manual Model MSRRS SCN05 Electrical parameter 5V 500mA max Lithium Ion battery Replace only with original battery from Biozoom Charging battery only in ambi...

Страница 23: ...f the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference tha...

Отзывы: