BIONIZER SUPPORT PAGES
DISPLAY MESSAGES
Message....Ions:Off
Example
....
Meaning
....Ionizing has been completed for the day,
and now only the Pool Pump output is
operating.
Solution
.....This is a normal part of the Bionizer
operation, so no action is required.
Message....Red MAX OUTPUT LED flashes
Meaning
....The Bionizer unit is not able to generate
the full amount of output current, as per
Ionizing Output setting.
Solution
.....Check the anodes, as per page 20.
!
If the anodes are in good condition,
check Calcium Hardness level and
correct as necessary (See Pool Snap
Balance Chart).
!
If Calcium Hardness level is correct, add
one bag of salt per 50,000L pool size to
increase the conductivity of the pool
water.
Message....No RTC
Example
....
Meaning
....The real time clock function of the
Bionizer is faulty.
Solution
.....Switch off the power to the Bionizer
control unit for at 15 seconds. Switch
back on and check if this message has
been cleared. If the message persists,
contact your supplier or Bionizer for
instructions about returning the unit for
repair.
Message....Green SELF CLEAN LED Flashes
Meaning ....The SELF CLEAN LED shows the activity
of the self cleaning system of the
Bionizer. The LED flashes slowly for one
+/- polarity, then flashes quickly for the
reverse polarity.
The SELF CLEAN LED does not flash after
Ionizing has finished for the day, and the
“
” message is displayed.
Ions:Off
31