Field
Description
setting under Public Interface Mode.
Public Interface Mode
Specify how strictly the setting under Public Interface is
handled. Possible values:
•
< %
: Only the selected interface is used, whatever the pri-
orities in the current routing table.
•
$
: Depending on the priorities in the current routing
table, the selected interface is used if no more favourable
route is available via a different interface.
Public Source IP Ad-
dress
If you are operating more than one Internet connection in paral-
lel, here you can specify the public IP address that is to be used
as the source address for the peer's data traffic. Select whether
the Public Source IP Address is to be enabled.
The function is enabled with
"1
.
In the input field, enter the public IP address that is to be used
as the sender address.
The function is disabled by default.
Back Route Verify
Select whether a check on the back route should be activated
for the interface to the connection partner.
The function is enabled with
"1
.
The function is disabled by default.
MobIKE
Only for peers with IKEv2.
MobIKE In cases of changing public IP addresses, enables only
these addresses to be updated in the SAs without the SAs
themselves having to be renegotiated.
The function is enabled by default.
Note that MobIKE requires a current IPSec client, e. g. the cur-
rent Windows 7 or Windows 8 client or the latest version of the
bintec elmeg IPSec client.
Proxy ARP
Select whether your device is to respond to ARP requests from
its own LAN on behalf of the specific connection partner.
Possible values:
bintec elmeg GmbH
16 VPN
bintec RS Series
335