![BinTec RS353j Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/bintec/rs353j/rs353j_user-manual_2752938153.webp)
Field
Description
formation) or
.##
(i.e. without VLAN information).
9.2.2 Port Configuration
In this menu, you can define and view the rules for receiving frames at the VLAN ports.
Fig. 55:
LAN
->
VLANs
->
Port Configuration
The LAN->VLANs->Port Configuration menu consists of the following fields:
Fields in the Port Configuration menu.
Field
Description
Interface
Shows the port for which you define the PVID and processing
rules.
PVID
Assign the selected port the required PVID (Port VLAN Identifi-
er).
If a packet without a VLAN tag reaches this port, it is assigned
this PVID.
Drop untagged frames If this option is enabled, untagged frames are discarded. If the
option is disabled, untagged frames are tagged with the PVID
defined in this menu.
Drop non-members
If this option is enabled, all tagged frames that are tagged with a
VLAN ID to which the selected port does not belong are dis-
carded.
bintec elmeg GmbH
9 LAN
bintec RS Series
139