MK LIT (E5) 01/2021
page 156/172
Chamber size
240
720
Weight
Weight (empty)
Kg /
lbs.
375 /
827
584 /
1287
Temperature data
Temperature range
°C /
°F
-40 to +110
-40 to 230
-40 to +110
-40 to 230
Temperature fluctuation
± K
0.1 to 0.5
0.1 to 0.5
Temperature uniformity (variation)
± K
0.1 to 1.2
0.3 to 2.0
Average heating up time acc. to IEC 60068-3-5
K/min.
5.0
4.0
Average cooling down time acc. to IEC 60068-3-5
K/min.
3.5
3.4
Heating up time from -40 °C to 110 °C
minutes
40
96
Cooling down time from 110 °C to -40 °C
minutes
160
100
Max. heat compensation at 25 °C /
77°F
W
2000
3500
Electrical data
(model version MK056-230V)
IP-system of protection of the battery test chamber
acc. to EN 60529
IP
23
23
IP-system of protection of the safety module acc. to EN
60529
IP
20
20
Nominal voltage (+/-10%) at 50 Hz power frequency
V
400
400
Current type
3N~
3N~
Nominal power
kW
5.60
8.70
Power plug
CEE plug 5
poles, 16 Amp
CEE plug 5
poles, 16 Amp
Over-voltage category acc.
to
IEC 61010-1
II
II
Pollution degree acc. to IEC 61010-1
2
2
Over-current release category B, internal
A
3x 16
3x 16
Electrical data of the voltage and frequency changer
IP-system of protection acc. to EN 60529
IP
23
23
Nominal voltage (+/-10%)
at 60 Hz power frequency (input side)
V
480
480
Current type
3N~
3N~
Nominal power
kW
9
13
Over-voltage category acc.
to
IEC 61010-1
II
II
Pollution degree acc. to IEC 61010-1
2
2
Fuse
A
16
16
Environment-specific data
Noise level (mean value)
dB(A)
62
65
Noise level (mean value) with voltage and frequency
changer
dB(A)
67
67
Energy consumption at +20 °C /
68 °F
Wh/h
1300
1900
Filling weight of refrigerant R 452A (GWP 2140)
kg /
lbs.
1.40 /
3.09
3.20 /
7.10
*
Used to calculate the LEL
Note:
Chambers with voltage and frequency changer: Average heating up time reduced by 0.3 K/min each.
All technical data is specified for unloaded chambers with standard equipment at an ambient temperature
of +22 °C +/- 3 °C /
71.6 °F +/- 5.4 °F
and a power supply voltage fluctuation of +/-10%. Technical data is
determined in accordance to BINDER Factory Standard Part 2:2015 and DIN 12880:2007.
All indications are average values, typical for chambers produced in series. We reserve the right to
change technical specifications at any time.
Содержание 9020-0402
Страница 159: ...MK LIT E5 01 2021 page 159 172 30 7 Dimensions LIT MK 240 dimensions mm...
Страница 160: ...MK LIT E5 01 2021 page 160 172 LIT MK 720 dimensions mm...
Страница 161: ...MK LIT E5 01 2021 page 161 172 31 Certificates and declarations of conformity 31 1 EU Declaration of Conformity...
Страница 162: ...MK LIT E5 01 2021 page 162 172...
Страница 163: ...MK LIT E5 01 2021 page 163 172...
Страница 165: ...MK LIT E5 01 2021 page 165 172...
Страница 166: ...MK LIT E5 01 2021 page 166 172 31 3 Safety concept certificate from T V S d...
Страница 173: ......