Installation, Operation and Maintenance Manual
VCIOM-08500-EN
Appendix
Appendix
D.2
Instructions for Proper Installation
WARNING
Before installation, it is mandatory to check if the nameplate associated with the
extension for additional entry specifies the appropriate degree of protection and ambient
temperature limits as requested by the rules applicable to the plant/location where the
ICON3000 is installed.
Installation in environments with the presence of an explosive atmosphere not covered by the
specified grade of protection, or in environments that could reach a temperature higher than
the maximum specified on the label, will invalidate the safety warnings and the warranty.
NOTICE
Check that the label (as shown by the example Figure D-4) is fixed to the unit and is complete
with all the appropriate information.
D.2.1
Marking
Figure D-4
Template of the label for ICON3000 / ICON3000AD / ICON3000LP
IECEx INE XX.ZZZZ
= IECEx reference certificate (CoC)
XX ATEX ZZZZ
= ATEX reference certificate
0080
= Notified body for ATEX quality assurance (INERIS)
II
= Group II (surface industries)
2
= Category 2 apparatus
G
= Explosive atmospheres caused by gas, mists, or vapors
D
= Explosive atmospheres caused by gas dusts
IP66/68
= Degree of protection