Installation, Operation and Maintenance Manual
VCIOM-15345-EN Rev. 1
February 2022
53
Customizing Biffi EHO
Section 8: Customizing Biffi EHO
8.4
EHO Configuration Menu
NOTICE
Feedback Only Factory Set parameters cannot be changed. If an attempt is made to
change a Feedback Only Factory Set parameter, all LEDs on the LDM will blink for 2 s and the
parameter's value will remain unchanged.
Menu Name
Menu
Key
Configuration/
Calibration Value
Default
Action
SETUP
Enter Setup to set parameters of the Biffi EHO.
See Section 8.1 for instructions to get into the
EHO Configuration Menu.
SU
Yes/No
N/A
FIND
Biffi EHO parameter quick search feature.
See Section 8.1 for instructions on how to use the
Biffi EHO quick search feature.
Fn
Yes/No
N/A
CHANGE SETTINGS
Allows user to make changes to the configuration
settings.
CH
Yes/No
N/A
PASSCODE
User must enter a passcode to make any changes
to the parameters of the EHO.
PC
0 0 0 0
(Firmware after 2018)
4 8 6 3
(Firmware before 2018)
N/A
VALVE CONTROL SETUP
Parameters related to controlling the actuator.
CS
Yes/No
N/A
CONTROL MODE
Set the method of remote control.
See wiring diagram for remote control
configurations.
CO
0 = 2 Wire
1 = 3 Wire
2 = 4 Wire
3 = Analog
4 = Network
1 = 3 Wire
ACTUATOR CLOSE DIRECTION
The actuator closing direction.
Note: This will be factory set.
Cd
0 = Close CCW
1 = Close CW
Feedback Only
VALVE CLOSE DIRECTION
Configure the close and open position of
the valve.
Note: This will be factory set.
rt
0 = CW Valve
1 = CCW Valve
Feedback Only
LED COLOR
Change color of LEDs used to indicate actuator
status (Open/Close/Opening/Closing).
LE
0 = Run LED Red,
Port LED Green
1 = Run LED Green,
Port LED Red
0 = Run LED Red,
Port LED Green
ENCODER POSITION
Reports if the encoder is installed properly. If the
encoder is replaced or out of position, user must
check this parameter to determine if the encoder
has been set to the correct position.
Note: This is factory set.
EP
0 = Incorrect Position
1 = Correct Position
Feedback Only
Table 13.
Configuration Table (1)