41
SIRIO
(1)
The alarm E16-VOLUME is a mere signal, that does not cause a
block, but that indicates a progressive reduction of the water flow
in the pump - electro-valve circuit or an inefficiency of the volume
meter, this signal pre-announces an imminent failure of the E04 -
PUMP.
There are also other non-blocking signals which signal that the
regeneration of the descaler resins, blades or filters is necessary.
The number of entries beyond which the regeneration is deemed
necessary is set in the OPTIONS menu; the display messages
foreseen are:
-
*
to indicate the error
E16 VOLUME
-
α
αα
αα
to indicate
resin
regeneration
-
&
to indicate the substitution of the
filters
-
$
to indicate the substitution of the
grinder
blades
-
#
to indicate the substitution of the
filters
and of the
grinder
blades
-
%
%
%
%
%
to indicate
resin
regeneration and the substitution of the
grinder
blades
-
Ω
Ω
Ω
Ω
Ω
to indicate
resin
regeneration and the substitution of the
filters
-
πππππ
to signal the regeneration of
resins
, substitution of the
filters
and the
grinder
blades
If one of the above mentioned symbols appears on entering
SERVICE
mode an
ALARM
message will appear followed by a
symbol indicating that regeneration is necessary.
12.0 ACCESSORIES KIT
- PUMP KIT
- CLOCK AUDIT KIT
- MDB KIT
- ELECTROMECHANICAL STROKE COUNTER
- OVERSIZED PRODUCT CONTAINERS
- PURIFIER MONO-HEATER
11.0 TROUBLESHOOTING GUIDE FOR THE FAILURES OR MOST COMMON ERRORS
In the function SERVICE, the failures, when present are immediately displayed in the follow manner:
There is also a
unit presence
safety device (micro-switch
mounted on the boiler unit support) in versions with plastic unit;
in the absence of this unit the machine indicates SELECTION
WITHOUT ESPRESSO COFFEE.
The presence of the following is also indicated:
- coffee unit
- water
- coffee
- cups
- dreg container empty
safety elements:
- coffee heater thermostat
- door switch
- mechanical anti- flooding
- pump, grinder, coffee delivery unit motor (timed regulation).
Display message
Probable cause
Remedy
E01
CUPS
No cup (blocks machine).
Fill up the relative column.
E03
COFFEE UNIT
The Fresh Brew unit is blocked, either in piston
movement or blockage of shower unit, which means
that movement has not occurred within the timeout
limit of 8/6 (blocks the coffee/tea selections).
E94
AIR PUMP
Lack of the pressure necessary during the
infusion period (generated during a specific
pressure withholding stage of the system)
(blocks the tea/coffee selections).
E06
PRESSURE PROBE
The pressure probe has either short-circuited or
is open (detached) (blocks the coffee/tea
selections).
E07
SCALE FACTOR
The scale factor sent by the executive payment
system exceeds 250 (non-blocking).
E08
NO WATER
Water fails to arrive from the water mains
(machine blocking). After a period of 4 minutes
in which no water presence is detected in the
mains water system. The machine is blocked.
E21
OVERFLOW
Dregs bucket full (blocking the machine).
E11
NTC PROBE
Temperature probe has either short circuited or
is open (detached) (blocking the machine).
E17
NOZZLE MOTOR
Nozzle system not working (blocking the
machine).
E18
STEAM
Presence of steam in the boiler (non blocking).
Содержание SIRIO FRESH BREW