1
5
INDOOR UNIT INSTALLATION
If the wrapped bundle of refrigerant pipes, cable wires and drainage hose is already installed in the
wall, use the procedures below.
i. Hook the top of the indoor unit onto the mounting plate without piping and wiring connected.
ii. Lift the bottom of the indoor unit away from the wall. Unbend the bracket on the mounting bracket
so that the indoor unit can be propped up enough to create enough space to work. Install the
piping, wiring and drainage hose per Steps 4 through 7.
iii. Re-bend the bracket and snap the unit into mounting bracket.
After the refrigerant pipes, cable wires and drainage hose are all installed on the indoor unit, bundle
them with insulating tape before passing them through the wall hole.
7.1 Arrange the pipes, cables and drainage hose as shown below:
7.2 Use insulating tape to wrap the refrigerant pipes, cable wires and drainage hose together tightly.
8.1 Carefully pass the wrapped bundle of refrigerant pipes, cable wires and drainage hose through
the hole in the wall.
8.2 Hook the top of the indoor unit onto the mounting plate.
8.3 Apply a slight pressure to the left and right side of the indoor unit. Make sure the indoor unit is
hooked firmly.
8.4 Push the bottom of the indoor unit against the mounting plate until it snaps into the mounting
plate.
Step 7: Wrap Piping and Cable
Step 8: Mount Indoor Unit
Refrigerant Piping
Drainage Hose
Cable Wiring
Insulation Tape
Note:
i. Make sure the drainage hose is at the bottom.
ii. Avoid crossing over and bending parts.
INDOOR UNIT INSTALLATION