background image

Step 3

Step 1

Operation

Steps

Step 4

Step 2

Step 5

Registration

Account

Download and

Install APP

Operation

Items

Login

Activate APP

Add Device to control

YES

YES

New Account

YES

YES

YES

NO

YES

Re-install APP

(registered before)

YES

YES

Registered Device will remain.

Operation guideline.

 

Please take below simple guideline instruction as reference.

Note If you registered the account and added device before, when you re-install the APP again and login,
              the added device will remain .

FCC Caution (

   

FCC ID: 2AJCLTWAC-TYWFS)

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
The distance between user and device should be no less than 20cm.

Let

'

s

 

get start!

Содержание 18K-36K

Страница 1: ...uctless Mini Split Air Conditioner Customer Technical Support information Please contact us BEFORE returning product Website www auxXsa com Contact Phone 1 909 979 9892 Mon ri 9am 5pm PST Email support auxusa com ...

Страница 2: ......

Страница 3: ...anged without notice For the most up to date version of the instructions please visit www dialmfg com ms technical data CONTENTS SAFETY PRECAUTIONS AND RECOMMENDATIONS 1 IDENTIFICATION OF PARTS 4 REMOTE CONTROL 6 OPERATING INSTRUCTIONS 7 INSTALLATION REQUIREMENTS 8 INDOOR UNIT INSTALLATION 9 OUTDOOR UNIT INSTALLATION 14 TEST OPERATION 17 MAINTENANCE 19 TROUBLESHOOTING 20 ...

Страница 4: ...able governing regulations The indoor unit must be protected by installing a fuse of suitable capacity for the maximum input current or with another overload protection device Before accessing the wiring terminals on the unit all power circuits must be disconnected from the power supply Ensure that the voltage from the mains electric ity corresponds to that stamped on the rating plate of the unit ...

Страница 5: ... be used for any other purpose such as for drying clothes cooling food etc Have repairs carried out only by a qualified tech nician Incorrect repair could expose the user to the risk of electric shock etc Always use the appliance with the air filter in place Running the air conditioner without an air filter could cause an excessive accumulation of dust or dirt on the inner parts of the device caus...

Страница 6: ...t not be used for any other purpose such as for drying clothes cooling food etc A prolonged exposure to the flow of cold air of the conditioner could have negative effects on plants and animals Do not obstruct the air inlet or outlet of the indoor or the outdoor unit The obstruction of these openings can cause a reduction in the operative efficiency of the air conditioner with possible consequent ...

Страница 7: ...ipe Indoor Unit Outdoor Unit Gas Valve Low Pressure Valve Liquid Valve High Pressure Valve Air Outlet Air Outlet Air Filter Screens HEPA Air Filter 1 per Filter Screen Note The appearance of the units that have been purchased may not correspond to the above product image IDENTIFICATION OF PARTS ...

Страница 8: ... function is the same Indoor Display No LED Function 1 Indicator for Timer Temperature and Error Codes 2 Lights up during Timer operation 3 SLEEP mode 4 The symbol appears when the unit is turned on and disappears when the unit is turned off 5 The symbol appears when power is on 2 3 1 1 2 4 3 5 ...

Страница 9: ...ode Fan speed Auto low low mid mid mid high high TURBO function Mute function Up down auto swing Temperature indicator Meaning Left right auto swing SLEEP function Timer Battery indicator Auto Mode Health function I FEEL function ECO Mode 8 heating function o C Signal indicator Gentle wind Child Lock Display ON OFF No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 6 ...

Страница 10: ...ff the function SLEEP SLEEP 10 To switch on off the LED display DISPLAY To stop or start horizontal louver movement or set the desired up down air flow direction 12 13 To switch on off the I FEEL function I FEEL 14 To switch on off the MUTE function MUTE Long press to activate deactivate the GEN function depending on models To stop or start horizontal louver movement or set the desired left righta...

Страница 11: ...remote control at a distance of at least 1m from the television or other electrical appliances For some model each time when insert the batteries in the remote controller for the first time you can set the Cooling only or Heating pump control type As soon as you insert the batteries turn off the remote controller and operate as below 1 Long press the MODE button until the icon flash to set the Coo...

Страница 12: ...e beep Cooling Mode Standby Heat Pump Only twice in 3 seconds Two beeps Running short period Temperature Cooling Dry Room Temperature 63 F 90 F 17 C 32 C Outdoor Temperature 5 F 75 F 15 C 24 C 4 F 75 F 20 C 24 C T1 Climate 59 F 122 F 15 C 50 C Low Temp Cooling 5 F 122 F 15 C 50 C T3 Climate 59 F 131 F 15 C 55 C Mode ...

Страница 13: ...15g m 30g m 25g m erant used R410A R32 R410A R32 PIPE Size Newton meter N x m Kilogram force meter kgf m 1 4 ø 6 35 18 20 24 4 27 1 2 4 2 7 3 8 ø 9 52 30 35 40 6 47 4 4 1 4 8 1 2 ø 12 45 50 61 0 67 7 6 2 6 9 5 8 ø 15 88 60 65 81 3 88 1 8 2 8 9 Minimum Wire Cross 2 AWG Socket or Switch A 8 0 75 18 AWG 10 20 8 and 10 1 0 17 AWG 10 20 10 and 15 1 5 16 AWG 16 32 15 and 24 2 5 14 AWG 25 32 24 and 28 4 ...

Страница 14: ...e unit 1 7 Filter should be easily accessible for cleaning 1 8 1 9 1 10 1 11 For ETL cer fica on area Cau on Mount with the lowest moving parts at least 8 2 4 m above floor or grade level Do not install in a laundry room or by a swimming pool or other corrosive environment Minimum Indoor Clearances 20cm 8 inches 13cm 5 inches 13cm 5 inches Ceiling Floor ...

Страница 15: ...Determine the location of the hole based on the position of the mounting plate 3 2 The hole should be at least 2 3 4 inch 70mm diameter and angled downwards towards the exterior wall to facilitate drainage refer to drawing below 3 3 Fit the wall sleeve and wall sleeve cover both are optional parts to protect the connection parts Step 2 Install Mounting Plate Step 3 Drill Hole in Wall ø 2 8 70mm In...

Страница 16: ...ap the joint with insulation until after the leak test is completed 4 1 Based on the wall hole position select the appropriate piping routing option There are three ways to route the piping for the indoor unit as shown in the figure below In Option 1 or 3 cut the plastic knock out along the groove on the side of the indoor unit with a cutter for the pipes to pass through 4 2 Unroll the connecting ...

Страница 17: ...e the cable size to use 6 2 Open the front panel of the indoor unit 6 3 Remove the electric control box cover to access the terminal block 6 4 Unscrew the cable clamp 6 5 Insert one end of the cable into the control box from the back at the right end of the indoor unit 6 6 Connect the wires to the corresponding terminals according to the wiring diagram on the electric control box cover 6 7 Tighten...

Страница 18: ... them with insulating tape before passing them through the wall hole 7 1 Arrange the pipes cables and drainage hose as shown below 7 2 Use insulating tape to wrap the refrigerant pipes cable wires and drainage hose together tightly 8 1 Carefully pass the wrapped bundle of refrigerant pipes cable wires and drainage hose through the hole in the wall 8 2 Hook the top of the indoor unit onto the mount...

Страница 19: ...Insert the drainage adapter into the hole at the bottom of the outdoor unit 2 3 Connect the drainage hose to the adapter 3 1 Use the feet of the outdoor unit to mark the location for the anchor bolts 3 2 Anchor the bolts to the installation base 3 3 If applicable install 4 rubber pads over the hole before placing the outdoor unit Op tional This will reduce vibrations and noise 3 4 Place the outdoo...

Страница 20: ... cap on each valve port Check that valves are clean 5 3 Remove the plastic cover in the pipe ports and check that the ports are clean 5 4 Fit the flare of the pipe into the valve port Screw the pipe flare nut onto the valve port by hand 5 5 Use a wrench to hold the body of the valve port and a torque wrench to tighten the flare nut Refer to the Torque Parameters table on the INSTALLATION REQUIREME...

Страница 21: ...minutes making sure that the rebound of compound gauge pointer does not exceed 0 005 MPa 6 9 Open the low pressure valve counterclockwise for 1 4 turn with a closed socket wrench to let a little refrigerant fill into the system Close the low pressure valve after 5 seconds and quickly remove the pressure hose 6 10 Check all indoor and outdoor joints for leakage with soapy water or leak detector 6 1...

Страница 22: ...frigerant Leakage Detection Check for leakage at the pipe connection points of the indoor unit and at the two valves of the outdoor unit Foam detection method Apply soapy water or foam evenly on the parts where leakage may occur and observe whether bubbles appear or not No bubbles indicate no leakage detected Leak detector method Use a professional leak detector and follow the directions to detect...

Страница 23: ...om the drainage hose 4 3 If the louver and deflectors optional operate properly 5 Observe the test run state of the air conditioner for at least 30 minutes 6 After a successful test run return to the normal settings and press the ON OFF button on the remote controller to turn off the unit 7 Demonstrate to the user how to use the air conditioner and inform the user to read the wireless remote contr...

Страница 24: ...ce Clean the Filter After removing the filter screen remove and inspect the HEPA filters If the HEPA filters are dirty replace the HEPA filters before reinstalling the filter screens Tip Clean the filter regularly to ensure clean healthy and efficient operation of the air conditioner HEPA filters should be replaced at least every 6 months Service and Maintenance If the air conditioner will not be ...

Страница 25: ...e expansion or contraction of the front panel due to variations in temperature and does not indicate a problem Insufficient Airflow Either Hot or Cold Unsuitable temperature setting Obstructed air conditioner intakes and outlets Dirty air filter Fan speed set at minimum Other sources of heat in the room No refrigerant The Appliance Does Not Respond to Commands Remote control is out of range to the...

Страница 26: ...gs endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter the food chain Display Description of the Issue Indoor room temperature sensor fault Indoor pipe temperature sensor fault Outdoor pipe temperature sensor fault Refrigerant system leakage or fault Malfunction of indoor fan motor Outdoor ambient temperature sensor fault Indoor and ou...

Страница 27: ......

Страница 28: ...te This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause h...

Страница 29: ...ENTS Wi Fi Module specification and basic information 1 Download and Install the App 2 Activate APP 3 Registration 4 Login 6 Add device 8 Air conditioner control 10 Account management 28 Trouble Shooting 30 ...

Страница 30: ...it Open the front panel the Wi Fi module is nearby the electric box cover or on the panel RESET SN Reset button Connecting cable 2 Basic parameters for Wi Fi module 2 400 2 500GHz Protocol stack support IEEE 802 11 b g n channels 1 14 Network frequency Parameters IPv4 IPv6 TCP UDP HTTPS TLS MulticastDNS Security support WEP WPA WPA2 AES128 Details Standards of WLAN Network type support STA AP STA ...

Страница 31: ... QR codewith a browser scanner download andinstall the APP Method2 Open theGoogle Play Store on your smart phoneand search SmartLife SmartHome ownload and install the APP For IOS smartphone Method1 Please scanthe QR codeand follow the tips toget into AppStore download and install the APP Method2 Open theApple AppStore on your smartphone and search SmartLife SmartHome download and install the APP S...

Страница 32: ...n then enter the activate code and tap CONFIRM SmartLife SmartHome OR BHI Activate QR code and activation code Note Without the QR code or activation code you can t active the APP and using it please keep them safe Scan Scan the activation QR code from instructions or device or Enter Activation Code or Enter Activation Code CANCEL CONFIRM The first time the app is used it will need activating ...

Страница 33: ...nce with the latest laws and regulations By clicking Agree you agree that you have fully read understood and accepted all the content of the revised Privacy policy Please take your time to read the Privacy Policy If you have anyquestion please contact us atany time Privacy Policy Disagree Agree A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Country Choosed A Afghanistan Albania Algeria Angola...

Страница 34: ...cluding character numbers Login Login 1 Tap Log in with existing account 2 Enter your registered account and password 3 Tap Log in button Log in with existing account Register Done Enter verification code Verification code is sent to your email Resend 55s Login Login means that you agree with User Agreement and Privacy Policy Log in Forgot password enter the password enter your account e mail here...

Страница 35: ...dd family Done Family Location Set location Smart devices in rooms Living Room Master Bedroom Second Bedroom Dining Room Kitchen Study Room Add Room You can change the room settings anytime My home choose the recommended room or make a new room then tap Done Room Name Add Room Done Recommended 6 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Allow Smart Life to access this device s location A...

Страница 36: ... Enter the verification code received by your e mail 4 Set the new password and tap button Done Login Email address Log in Password Forgot password Forgot password X Obtain verification code Enter verification code Verification code is sent to your email Resend 55s Set Password 6 20 characters for password including character numbers Done Login means that you agree with User Agreement and Privacy ...

Страница 37: ...first Method1 When there is a DISPLAY key on the remote control press the DISPLAY key 6 times in the time of 8 seconds when there is no DISPLAY key on the remote control press the ECO key 6 times in the time of 8 seconds until the device beeps twice and the LCD screen show CF Next Cancel Confirm the device is reset Resetting Devices Method2 Press the General key 9 times in the time of 8 seconds un...

Страница 38: ... Split Air Conditioner logo 4 Input the password of the Wi Fi which the same as your smart phone connected then tap Next 5 Tap in the upper right corner and choose AP Mode then follow the comments on the screen to reset the Wi Fi module then check Confirm the device is reset and tap Next 6 Read the instruction carefully and tap Connect now 7 In the network setting screen select SmartLife and tap 8...

Страница 39: ...ormation Welcome home V All Devices Living Room room Master Bed Home Me Sample1 Sample2 Turned off Already On ON OFF Fan Speed Precision Air Flow More Eco Sleep Mode Timer Sample1 77 Cool 0 73 F F Set Temperature Timer Function Fan Mode Sample2 10 Control form1 Control form2 Note There are two different control forms base on different software or Wi Fi module firmware Please read the manual carefu...

Страница 40: ...e Sample2 Turn ON OFFthe air condi oner Device details and management Increase the se ng temperature Decrease the se ng temperature The main control interface Back to the Home screen Indicator of se ng temperature Selected Mode Fan speed Func ons indicator Control form1 ...

Страница 41: ...rature to cancel the Mode setting 73 F Set Temperature Timer Function Fan Sample2 Mode Fan Dry Feel Cool Heat Mode 73 F Set Temperature Timer Function Sample2 Mode Fan Fan Med Low Auto High Control form1 Select fan speed 1 Tap Fan to pop up the Fan screen 2 Select one of the fan speed High med Low Auto 3 Tap anywhere around the setting temperature to cancel the selection 12 ...

Страница 42: ... swing with direction of UP DOWN LEFT RIGHT 4 Tap anywhere around the setting temperature to cancel the Function setting 73 F Set Temperature Timer Fan Sample2 Mode Function UP DOWN LEFT RIGHT Turbo Sleep ECO Function 73 F Set Temperature Timer Function Fan Mode Sample2 Control form1 Timer adding 1 Tap Timer to pop up the Add Timer screen 2 Tap Add Timer 13 WLAN Add Timer Add timer ...

Страница 43: ...n Mode Fan Set Temperature Function Cool Auto 23 C Cancel Add Timer Save 15 28 14 27 13 26 12 25 16 29 17 30 18 31 Select days to use Smart Mode Timer Off Mon Tues Wed Thur Fri Sat Sun Timer On Control form1 Timer Management WLAN Add Timer Add timer Timer accuracy is 30 seconds 12 20 Once Timer Off 12 20 Mon Tue Wed Thurs Timer On 16 Cool Turbo UP DOWN 1 Tap the bar of timer to edit the Timer like...

Страница 44: ...ed Func ons indicator Note it may appear slightly different depending on the air conditionermodel Example as below Tips Different backgroundfor different mode Cool Heat Dry Fan Auto ON OFF Fan Speed Precision Air Flow More Eco Sleep Mode Timer Sample1 77 F Cool 0 Fan Speed Swing Flow Eco Sleep Mode Timer Turbo Func on Bu ons Control form2 The main control interface ...

Страница 45: ...FF Fan Speed Precision Air Flow More Eco Sleep Mode Timer Sample1 77 F Cool 0 1 Tap the Fan speed bu on 2 Choose your desired fan speed and tap it 3 Tap the X bu on to back the main control screen 4 The selected fan speed indicator will appear on the screen Back Sample1 77 Cool 0 Turbo Mid High Mid high Fan Speed X Mid Low Mute Auto Low F F F Mode Fan Speed Cool Fan Dry Heat Auto All speeds All sp...

Страница 46: ...rconditioner model Example asbelow Back Sample1 77 Cool 0 Swing Flow X Up Down Le Right F F F 17 Get verification code Precision Air Flow Up Down Flow Control Left Right Flow Control Downwards Swing Up Down Swing Upwards Swing Middle Fix Top Fix Upper Fix Lower Fix Bottom Fix Precision Air Flow Up Down Flow Control Left Right Flow Control Right Swing Left Right Swing Left Swing Middle Swing Center...

Страница 47: ... Speed Precision Air Flow More Eco Sleep Mode Timer Sample1 77 Heat 0 ON OFF Sample1 73 Cool 0 Fan Speed Swing Flow Eco Sleep Mode Timer Turbo ECO F ON OFF Fan Speed Precision Air Flow More Eco Sleep Mode Timer Sample1 78 Cool 0 Low Control form2 ECO func on F F 18 Note The Main controlscreen and ECOcontrol method mayappear slightly different depending on the airconditioner model Example asbelow M...

Страница 48: ...Cool 0 Sleep X Standard Child The aged Back Sample1 77 Cool 0 Sleep X Child The aged Standard Control form2 Sleep func on F F F F Air conditioner control 1 Tap the Sleep button 2 Choose your desired sleep mode and tap it 3 Tap the X button to back to the main control screen 4 The selected sleep mode indicator will appear on the screen 19 Note The Main controlscreen may appear slightly different de...

Страница 49: ...p Mode Timer Sample1 77 Cool 0 F Timer No Timer Timer 19 27 20 28 22 30 23 31 Save 21 29 Repeat Monday Switch OFF Once Monday Tuesday Wednesday Thursday Friday Saturday Sunday Cancel Repeat Confirm 20 Slide up or down to select time Tap repeat then tap your desired repeat days orOnce then tap Confirm your selection Timer 21 29 OFF Weekday ON Cancel Switch Confirm OFF Tap Switch then slide the scre...

Страница 50: ...5 Mode Cool Fan Speed Mid Precision Air Flow Up Down Swing Slide up or down to select time 21 Once Monday Tuesday Wednesday Thursday Friday Saturday Sunday Cancel Repeat Confirm Tap repeat then tap your desired repeat days orOnce then tap Confirm your selection Timer ON Cancel Switch Confirm OFF Tap Switch then slide the screen to chooseON and Confirm 16 19 ON Cool Mid Up Down Swing 25 M Timer 21 ...

Страница 51: ...p the right of the switch to enable the Timer 3 Delete the Timer Slide the list bar of the Timer from right to left until Delete button appear then tap delete Timer 16 19 ON Cool Mid Up Down Swing 25 M 21 29 OFF Weekday 04 30 OFF 22 Timer 16 19 ON Cool Mid Up Down Swing 25 M 21 29 OFF Weekday 04 30 OFF Slid left to disable the Timer Slid right to enable the Timer Timer 16 19 ON Cool Mid Up Down Sw...

Страница 52: ...hrough Wi Fi APP Buzzer Note Some air conditioner model don t have the more button 4 Tap the button to activate the Anti Mildew function if it is available on the screen After AC turning off it will start drying reduce residual moisture and prevent mould after function finish it will automatically turn off Anti Mildew Health 5 Tap the button to switch on off the healthy function if it is available...

Страница 53: ...utton to pop up the calenderthen select the date 8 Tap the button if it is available on the screen Check the details of the Self Cleaning function on User Manual 9 Tap the 8 Heat button if it is available on the screen This function help keep the room temperature over 8 Check the details of the 8 Heat function on User Manual Self Cleaning 8 Heat Control form2 More functions 10 Tap the Reservation ...

Страница 54: ... diagnosis 100 Complete Error code E0 Indoor and outdoor communication failure Self diagnosis Control form2 More functions 12 Tap the button if it is available on the screen 13 Tap the button if it is available on the screen In this function the air conditioner will blow soft airflow through the micro holes on the deflector Photosensitive Soft Wind This function allow the air conditioner to turn o...

Страница 55: ...fy Device Name Device Location Dining Room Check Device Network Check Now Device Sharing Device Info Feedback Check for Firmware Update Tap to change the device location to another room Tap to check the network status Tap to got the instruction for connecting the amazon alexa or Google Assistant voice controller Tap to check the Virtual ID Wi Fi name IP address MAC address Time Zone Wi Fi single s...

Страница 56: ... sharing members should hold pressing the home screen and slide down to refresh the device list the device will appear on the device list Details of device Adding sharing It is recommended to set permanent resident as family member to control the device Family Settings Add Sharing Completed Region China 86 Account number Details of device Adding sharing It is recommended to set permanent resident ...

Страница 57: ...nt Security Time Zone Universal Nickname Select a picture for the account from local album Edit name Cancel Save Account one Select the time zone Change the nick name of your account Account Security Phone Number Change Login Password Deactivate Account Location China Pattern Unlock Change Pattern Password Change the password like reset password on page7 Please carefully to deactivate the account ...

Страница 58: ...e and tap Home Management 2 Tap one of the families in the family list and get into Family Settings screen Family settings Family members Room Management 2 rooms Family Location Family Name My Home Remove Family Add Menber Nick name Account Tap to rename the family name Tap to get into Room Management Open the map automatically then you can set the location Add other account into this family to co...

Страница 59: ...LAN router mobile device and air conditioner WLAN module and connect air conditioner by CF mode again Before rebooting check nobody has already connected to same air conditioner 1 When air conditioner WLAN module is rebooted and app displays Device remove ignoring this confirmation will lead to mobile device losing control permission of the air conditioner Youwill need to connect the air condition...

Страница 60: ...operating properly test the outlet with another appliance C Check if electricity to the main power switch of the unit appears to be working D Make suere that both units are in the upright position IF NONE OF THE ABOVE SOLVES THE PROBLEM CONTACT A QUALIFIED TECHNICIAN CUSTOMER SERVICE If you have a problem with this product please contact the below DATED PROOF OF PURCHASE MODEL AND SERIAL REQUIRED ...

Отзывы: