D812123 00100_02
CLONIX U-LINK
17
ENGLISH
INSTALLATION MANUAL
TABLE “C” - LOGIC MENU - (
logic
)
Logic
Definition
Default
Cross out
setting
used
Optional extras
FIXED CODE
Fixed code
0
0
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
Protection
level
Setting the
protection
level
0
0
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmit-
ters by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added
to the receiver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
1
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
2
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0
logic setting
3
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
4
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops
radio interference, if any.
ADDRESS
Address
0
[ ___ ]
Identifies board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
TABLE “D” SLOTS CONFIGURATION MENU
(
conf.slots
)
SLOT PARAM.
Definition
Default
Cross out
setting used
Description
address
type
Slot input
operation type
configuration
0
0
The command received on this slot is sent to the other two u-link slots, keeping the target address constant, if
there is a B EBA U-LINK 485 board on it, the command is sent to downstream devices and resolved if the right
address is found.
1
Each command received on this slot is locally run thus on Clonix U-Link
2
Each command received on this slot is re-routed to the address indicated in the remote ID field. This command is
sent to the other two u-link slots, if there is a B EBA U-LINK 485 board on it, the command is sent to downstream
devices and resolved if the right address is found.
remote ID
Remote
Command
address
0
[ ___ ]
Address of the board where the command is re-routed. Only taken into account if the Address type setting is 2.
open
Open
Command re-
mapping
1
0
The Open command received via U-LINK protocol does not activate any output
1
The Open command received via U-LINK protocol activates output OUT 1
2
The Open command received via U-LINK protocol activates output OUT 2
3
*
The Open command received via U-LINK protocol activates output OUT 3*
start
Start
Command re-
mapping
1
0
The Start command received via U-LINK protocol does not activate any output
1
The Start command received via U-LINK protocol activates output OUT 1
2
The Start command received via U-LINK protocol activates output OUT 2
3
*
The Start command received via U-LINK protocol activates output OUT 3*
stop
Stop
Command re-
mapping
2, 3
*
0
The Stop command received via U-LINK protocol does not activate any output
1
The Stop command received via U-LINK protocol activates output OUT 1
2
The Stop command received via U-LINK protocol activates output OUT 2
3
*
The Stop command received via U-LINK protocol activates output OUT 3*
ped
Pedestrian
command re-
mapping
1
0
The Pedestrian command received via U-LINK protocol does not activate any output
1
The Pedestrian command received via U-LINK protocol activates output OUT 1
2
The Pedestrian command received via U-LINK protocol activates output OUT 2
3
*
The Pedestrian command received via U-LINK protocol activates output OUT 3*