D812123 00100_02
16 -
CLONIX U-LINK
INSTALLATION MANUAL
TABLE “A” – RADIO MENU (
RADIO
)
Logic
Description
OUT 1 add
Add Key to output OUT 1
associate the required key to the OUT 1 output
OUT 2 Add
Add Key to output OUT 2
associate the required key to the OUT 2 output
OUT 3 Add
*
Add Key to output OUT 3
associate the required key to the OUT 3 output
aut.
Automatically associates T1 to OUT 1, T2 to OUT 2, T3 to OUT 3 (where present).
erase 2048
Erase List
WARNING! Erases all memorized transmitters from the receiver’s memory.
cod RX
Read receiver code
Displays receiver code required for cloning transmitters.
* only on CLONIX UNI AC U-LINK 230.
TABLE “B” - OUTPUT CONFIGURATION MENU (
outputs
)
OUTPUT
Definition
Default
Cross out setting used
Description
out1
Out 1 output
configuration.
20-21
monos
monos
Pulse or non-latching type output, the associated output relay is attracted for 1 second.
bist
Jog type output (latching), the associated relays switches status each time the transmitter
key is pressed.
timed
Each time the transmitter key is pressed the output
relay remains attracted for an interval of time that can
be set according to the following table. Pressing the
key during the count cycle resets the count.
See table B1
antipanic
The associated output relay switches status if the transmitter key is held down for more than 5
seconds. All transmitter keys on the receiver are automatically equipped with the anti-aggression
function regardless of their configuration, thus the output need not be assigned a key (T1,T2,T3
or T4) Relay switching lasts 10s.
If linked to a transmitter key and held down for less than 5 sec., it behaves like a non-latching output.
Only one output can be configured with anti-aggression mode.
out2
Out 2 output
configuration.
22-23
monos
monos
Pulse or non-latching type output, the associated output relay is attracted for 1 second.
bist
Jog type output (latching), the associated relays switches status each time the transmitter
key is pressed.
timed
Each time the transmitter key is pressed the output
relay remains attracted for an interval of time that can
be set according to the following table. Pressing the
key during the count cycle resets the count.
See table B1
antipanic
The associated output relay switches status if the transmitter key is held down for more than 5
seconds. All transmitter keys on the receiver are automatically equipped with the anti-aggression
function regardless of their configuration, thus the output need not be assigned a key (T1,T2,T3
or T4) Relay switching lasts 10s.
If linked to a transmitter key and held down for less than 5 sec., it behaves like a non-latching output.
Only one output can be configured with anti-aggression mode.
out3
*
Out 3 output
configuration.
24-25
monos
monos
Pulse or non-latching type output, the associated output relay is attracted for 1 second.
bist
Jog type output (latching), the associated relays switches status each time the transmitter
key is pressed.
timed
Each time the transmitter key is pressed the output
relay remains attracted for an interval of time that can
be set according to the following table. Pressing the
key during the count cycle resets the count.
See table B1
antipanic
The associated output relay switches status if the transmitter key is held down for more than 5
seconds. All transmitter keys on the receiver are automatically equipped with the anti-aggression
function regardless of their configuration, thus the output need not be assigned a key (T1,T2,T3
or T4) Relay switching lasts 10s.
If linked to a transmitter key and held down for less than 5 sec., it behaves like a non-latching output.
Only one output can be configured with anti-aggression mode.
* only on CLONIX UNI AC U-LINK 230.
Table B1
Parameter value
Time interval
1
30s
2
60s
3
2 minutes
4
5 minutes
5
15 minutes
6
30 minutes
7
1 hour
8
2 hours
9
12 hours