Maintenance
BETTCHER
Industries, Inc.
Manual No. 102481
April 17, 2015
Maintenance
Whizard Quantum
®
Air Operating Instructions and Parts List
5-47
Disassembly of Power Unit
(Continued)
STEP 3: Slide Components Out Of Handle
•
Slide the seal plate, gear head,
air motor, adapter plate,
muffler, and retainer out of the
handle.
•
The parts should slide out
easily. If the parts do not slide
out, tap the handle lightly
against a plastic block to
dislodge the parts.
STEP 4: Separate Seal Plate And Gear Head Assembly
•
Separate the seal plate and gear head assembly
from the air motor, adapter plate, muffler, and
retainer.
Handle
Seal Plate
Gear Head