5-23
Disassembly of Whizard Quantum
®
TRIMVAC
®
Handpiece
Step 1: Remove Blade from Handpiece:
Whizard Quantum
®
TRIMVAC
®
18:
•
Hold the tool with the blade side up.
•
Loosen only the left cover retaining
screw, using the supplied 3/32” hex
wrench.
•
Insert a screwdriver into the housing slot.
•
Using the frame support point, spread open the
housing, just far enough to remove the blade.
•
Carefully remove the blade.