7
METEO GREEN HE R.S.I.
Parameter
Symbol
R.S.I. 25 kW
R.S.I. 35 kW
Unit
Seasonal space heating energy efficiency class
-
A
A
-
Water heating energy efficiency class
-
-
-
-
Rated heat output
Pnominal
24
34
kW
Seasonal space heating energy efficiency
93
92
%
Useful heat output
At rated heat output and high-temperature regime (*)
P4
24,4
33,7
kW
At 30% of rated heat output and low-temperature regime (**)
P1
8,2
11,2
kW
Useful efficiency
At rated heat output and high-temperature regime (*)
88,3
87,9
%
At 30% of rated heat output and low-temperature regime (**)
98,5
97,3
%
Auxiliary electricity consumption
At full load
elmax
40,0
68,0
W
At part load
elmin
16,4
25,8
W
In Stand-by mode
PSB
6,3
7,7
W
Other parameters
Stand-by heat loss
Pstby
55,0
42,0
W
Pilot flame energy consumption
Pign
-
-
W
Annual energy consumption
QHE
42
58
GJ
Sound power level, indoors
LWA
58
60
dB
Emissions of nitrogen oxides
NOx
36
23
mg/kWh
For combination heaters
Declared load profile
-
-
Water heating energy efficiency
-
-
%
Daily electricity consumption
Qelec
-
-
kWh
Daily fuel consumption
Qfuel
-
-
kWh
Annual electricity consumption
AEC
-
-
kWh
Annual fuel consumption
AFC
-
-
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
6 - HYDRAULIC CIRCUIT
A. Water tank delivery (DO NOT USE)
B. Water tank return (DO NOT USE)
C. Heating
flow
D. Heating
return
G. Safety
valve
H. Drain
valve
I. Automatic
by-pass
L.
3-way motor valve
M. Circulator
N. Lower air vent valve
O. Expansion
vessel
P.
Return NTC sensor
Q. Primary
exchanger
R. Delivery NTC sensor
S. Upper air vent valve
T.
Air water separator
U. Manual bleed valve
V. Pressure
transducer
Z. Hydrometer
H
I
L
G
M
N
O
P
Q
R
S
T
U
V
Z
A
B
C
D
NOTE (if the external probe or the control panel or both devices are in the boiler) With reference to Delegated Regulation (EU) No. 811/2013, the data in
the table can be used for completing the product card and the labelling for ambient heating appliances, for mixed heating appliances, for assemblies of
appliances for ambient heating, and for temperature control devices and solar devices:
Component
Class
Bonus
External probe
II
2%
Control panel
V
3%
External probe + control panel
VI
4%