44
METEO GREEN HE R.S.I.
.
}'[^?`&<[@|^?^\>><&
|^['[?^{`''?&'??'?
RETURN and exit the HTG-PROG menu.
To stop at any moment the time bands programming, close the
cover of the panel.
The values set will not be memorized.
ou may exclude the heating schedule from one or more time ban-
ds. To do so, proceed as follows:
- set a time band: example
ON -
OFF as previously indi-
cated
- press ENTER
- or the second time band overtake the 24 hours by pressing the
+ button.
The display shows segments instead of the timetable, see the
`^[
|^['??&^>
By doing this operation, you excluded the second time band
from the heating schedule
- for the third time band overtake the 24 hours by pressing the +
button
The display shows segments instead of the timetable.
|^['??&^>
By doing this operation, you excluded the third time band from the
heating schedule.
The boiler will operate according to the time band set and will stay
off the rest of the time.
The relative room temperature is automatically assigned to each
time band set in the HTG-PROG menu (T-ROOM DES 1, 2, 3):
T-ROOM DES1
T-ROOM
DES2
T-ROOM
DES3
The default room temperatures are set for 20°C, but you may
adjust them, as already explained in paragraph 3.2.4 “Description
of menus” “USER” dedicated section.
} '[ ^??> '[>|[^\'`^[ [^[ |[^?&\]<[@ >?@<[@
'[ |^?-
grams are assigned these new values.
EXAMPLE OF PROGRAMMING
We consider that you want to set three heating time bands in 24
hours.
- time band 1: from 6.30 to 8.30
desired temperature 20°
- time band 2: from 12.00 to 15.00
desired temperature 18°
- time band 3: from 17.00 to 23.00
desired temperature 24°
In HTG-PROG MENU set the time bands.
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
ENTER
+
-
In USER MENU set the desired temperature:
T-ROOM DES1 20°C
T-ROOM DES2 18°C
T-ROOM DES3 24°C
The progress of temperature/time bands will be as shown in the
diagram.
You may set even temperatures for different time bands
Eg. T-ROOM DES-1 = T-ROOM DES-2
It is not possible to overlay the time bands.
HOTW-PROG (DO NOT USE
FOR METEO GREEN HE R.S.I.)
(domestic hot water schedule)
Permits programming three operating
time bands during the 24 hours.
Each time band is assigned a sanita-
ry temperature set in the USER menu
(T-DHW 1, 2, 3).
This function is enabled only for boilers with water tanks.
If the water tank is equipped with probe, you can set the desired
temperature; for boilers with thermostat, you have to set the water
temperature directly on the boiler.
To set the time bands, proceed as follows:
- go to HOTW-PROG
|^[
'[@<|]\<]]?'[^'@\?}'[[[
- with the + e – buttons select one of the available schedules
described below:
· Daily: you can schedule each day of the week separately. The
display will show each day: Monday, Tuesday, Wednesday, etc
· Holiday: you can schedule week days at the same time (Monday
to Friday) and Saturday and Sunday differently
· Sab-Dom: you schedule only Saturday and Sunday
· Weekly: you can schedule all the days of the week at the same
time (Monday to Sunday)
[]['\[@`][
'[&|^['??&^>
?^\}[[?&@
'[@<|]\<]]\||[\^\<&`^[
\}'[^'\-
'\<&`^[
fasce orarie/time bands
temperature/temperatures
°C
T-RIDOTTA
T-REDUCED
T-AMB2
T-ROOM DES 2
T-AMB1
T-ROOM DES 1
T-AMB3
T-ROOM DES 3
15
16
17
18
19
20
21
22
23
24
6.30
8.30
12.00
15.00
17.00
23.00
ON
OFF
ON OFF
ON OFF
ora
hour
fascia 1
time band 1
fascia 2
time band 2
fascia 3
time band 3
ENTER
+
-