METEO GREEN HE R.S.I.
21 - SERIAL NUMBER PLATE
Q nominal
capacity
P nominal
power
IP
protection
level
t max
temperature
NOx
NOx value class
230 V ~ 50 Hz IPX5D NOx:
Serial No.
Condensing Boiler EAN 80-18000-32117-1
Appliance category:
METEO GREEN HE R.S.I.
max gas pressure
MJ/h NG
MJ/h ULPG
min inlet pressure NG
min inlet pressure ULPG
IAPMO Certificate No. GMK10203
Safety valve setting = Weight (net) =
max water pressure
min water pressure
t max
max min
Q kW
P 80°-60° kW
P 50°-30° kW
CO
2
limits (all models):
22 - ADJUSTMENTS
The boiler has already been factory adjusted by the manufacturer. If a new
adjustment is required, for example, after extraordinary maintenance, replac-
ing the gas valve or converting fro m natural gas to LPG, proceed as follows.
Maximum and minimum power, minimum and maximum heating,
must be adjusted in the indicated sequence by qualified staff
.
- Unscrew the lower cover fixing screw (A-B) (Fig. 1.5).
- Pull the cover towards you and remove.
- Lift up the panel and turn it forwards
CALIBRATION & SERVICE operations must be performed with the
boiler in the OFF position. To do this, press the
button until the display
shows “- -” (Fig. FF).
During parameter modification operations, the “select functions” button
acts as an ENTER (confirm) button, the button acts as an ESCAPE
button. If no confirmation is given within 10 seconds, the value is dis-
carded and returns to the previously set one.
SETTING THE PASSWORD
To enter the password, and then setting the parameters, follow the procedure:
1.
Turn the boiler in OFF, press the ON / OFF button until the display shows
two horizontal lines “--”.
2.
Simultaneously press the button INFO and MODE 5“ until the display
shows:
In display 4 digits written intermittent “Code” - “0000”.
In display 2 digit visualized 00.
Press MODE to confirm and to enter their passwords by turning the encoder
DHW, and then always confirm the code by pressing another time MODE.
In the display 2-digit appears the number of the parameter, in the display
4-digit appears the value.
CALIBRATION PHASES
In this boiler we have the possibility of three different mode for three differ-
ent level of setting:
Level one Programmer Setting
Use password 53
With this mode is possible change all the parameter. This mode is useful for
personalize the boiler in function of the type of installation.
Level two Adjusting Setting (Calibration end Setting)
Use password 18
With this mode is possible change ONLY the parameter for setting the boiler.
E.g. this mode is useful when you need to change the gas.
Level three Combustion Analysis mode
Use password 19 (RANGE RATED & chimney sweeper function)
With this mode is possible do set up the maximum power in heating and
make the combustion analysis test at this power.
Parameter with password 18
PAR.
MEANING
UNIT
MIN
MAX
STEP
DEFAULT
1
Kind of gas- don’t change
--
1 = G20 - LPG
1
1
2
Power boiler
--
26 = (25 kW)
34 = (35 kW)
26-30
26-34
3
Thermal insolation of the house
ONLY IF IS CONNECTED THE EXTERNAL SENSOR
min
5
20
1
5
10
Tipe of sanitary DHW
--
0 =OFF
1 =Istant
2 =not used
3= Ext. Tank with
thermostat
4= Ext. Tank with NTC
sensor
5= not used
1
1
45
CH1 OTC (climatic curve)
ONLY IF IS CONNECTED THE EXTERNAL SENSOR
--
2,5
40
2,5
20
(continued)
CH1 = first CH circuit / CH2 = second CH circuit