15
METEO GREEN HE R.S.I.
- 1.13 -
sealing
rubber
- 1.14 -
Length of the intake duct (m)
25 R.S.I.
Exhaustion lenght (m)
0
5
10
15
20
25
30
35
40
45
50
55
60
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Length of the intake duct (m)
Exhaustion lenght (m)
35 R.S.I.
Rectilinear length means without bends, outlet ends and connections.
The fumes outlet duct must slope by 1% towards the condensate col-
lector.
Uninsulated fumes outlets are potential hazards.
The boiler automatically adapts ventilation according to the type of
installation and the length of the duct.
Do not obstruct or narrow the comburent air inlet duct in any way.
To install follow the instructions supplied with the kit.
Concentric outlets (Ø 80-125)
For this installation it is necessary to install the suitable adaptor kit. Ducts
may be placed in the most suitable direction for installation requirements.
For the installation process, follow the instructions supplied with the kit for
the specific accessory for condensation boilers.
Max linear length
concentric duct
Ø 80-125 mm
Pressure drop for each
bend (45°/90°) [m]
25 R.S.I.
14,85 m
1 / 1.5
35 R.S.I.
14,85 m
Twin outlets (Ø 80)
The split duct can be aimed in the most suitable direction for installation
needs. Upper cover not used (Fig. 1.13).
The combustion-supporting air intake duct must be connected to the entrance
after having removed the closing cap, attached with three screws, and having
attached a suitable adaptor.
The fumes outlet duct must be connected to the fumes outlet after having
installed a suitable adaptor.
For the installation process, follow the instructions supplied with the kit for
the specific accessory for condensation boilers.
The fumes outlet duct must slope by 1% towards the condensate col-
lector.
The boiler automatically adapts ventilation according to the type of
installation and the length of the duct. Do not obstruct or narrow the
comburent air inlet duct in any way.
For an indication of the maximum lengths of every single pipe, refer to
the graphs (Fig. 1.14).
Using longer ducts causes a loss in the power of the boiler.
Max length twin duct
Ø 80 mm
Pressure drop for each
bend (45°/90°) [m]
25 R.S.I.
32 + 32 m
1 / 1.5
35 R.S.I.
40 + 40 m
Rectilinear length means without bends, outlet ends and connections.