Beretta Exclusive GREEN HE C.S.I. 35 kW Скачать руководство пользователя страница 18

EXCLUSIVE GREEN HE C.S.I. - R.S.I.

 

24

 

 

 

 

16 - SETTING THE THERMOREGULATION 

– OPTIONAL with use of external sensor

 

 

Checking the connection with the external probe

 

!FTER CONNECTING THE EXTERNAL PROBE TO THE BOILER, USE THE ).&/ FUNCTION TO CHECK THAT THE PROBE HAS BEEN AUTOMATICALLY RECOGNISED  BY THE TEMPERATURE

 

control card. Immediately after installation, the value read by the probe may very well be higher then that measured by a reference probe.

 

%NABLE AND OPTIMISE THE 4(%2-/2%'5,!4)/. FUNCTION BY SETTING THE FOLLOWING PARAMETERS:

 

 

PARAMETER

 

490% /& "5),$).'

 

-!8)-5- (%!4).' 3%4 0/).4

 

-).)-5- (%!4).' 3%4 0/).4

 

%.!",% 4(%2-/2%'5,!4)/. 
&5.#4)/.

 

/&&3%4 4%-0%2!452% #526%

 

490% /& (%!4 2%15%34

 

 

AVAILABLE IN THE PROGRAMMING MODE

 

).34!,,!4)/. !.$ #!,)"2!4)/. & 3%26)#%

 

21 

).34!,,!4)/.

 

22 

).34!,,!4)/.

 

44 

).34!,,!4)/.

 

45 

).34!,,!4)/. !.$ #!,)"2!4)/. & 3%26)#%

 

51 

).34!,,!4)/.

 

 

 

To access the programming mode, consult “Programming parameters”.

 

PARAMETER 03. Type of building

 

In order to calculate delivery temperature, the temperature control system 
does not directly use the external temperature value but considers the heat 
insulation  of  the  building:  in  well-lagged  buildings,  external  temperature 
variations affect the ambient temperature less than they do in badly-lagged 
buildings. Use parameter 3 to set the heat insulation level of the building 
according to the following scheme:

 

 
 
 

If,  from  your  calculations,  you  obtain  an  intermediate  value  between  two 
curves, we suggest choosing the compensation curve closest to the value 
obtained.

 

Example: if the  value  obtained  from  the  calculations  is  8,  this  is  between 
curve 7.5 and curve 10. In this case, choose the closest curve, which is 7.5.

 

PARAMETER 51. Type of heat request

 

IF AN AMBIENT THERMOSTAT IS CONNECTED TO THE BOILER, SET 
PARAMETER 51 = 0 (graph 2).

 

The ambient thermostat makes a heat request when its contact closes, while 
it stops it when its contact opens. Though delivery temperature is automati- 
cally calculated by the boiler, the user may manually override it. By modifying 
(%!4).' ON THE USER INTERFACE, THE (%!4).' 3%4 0/).4 WILL NO LONGER BE 
AVAILABLE BUT JUST A VALUE THAT CAN BE SET FROM +5 TO -5

—# AS REQUIRED. 

-ODI-

 

fications to this value do not directly change delivery temperature but affect 
the calculation made to automatically determine its value by modifying the 
REFERENCE TEMPERATURE OF THE SYSTEM (o = 2o

—#).

 

&OR BOILERS lTTED WITH THE 3.!.2.!.  &UNCTION, IF THE !-")%.4 4(%2-/34!4

 

remains closed for a long time, the boiler automatically increases the delivery 
temperature which is added to the effect of the temperature control function.

 

New

 

Old

 

Hollow

 

Solid

 

Stones

 

7HEN THE !-")%.4 4(%2-/34!4 OPENS, THE BOILER AUTOMATICALLY RETURNS

 

       houses 

houses 

bricks 

bricks 

 

  

19 

14 

12 

 

  

20 

16 

15 

11 

 

  

19 

15 

14 

 

  

18 

12 

10 

 

 

 

PARAMETERS 21 and 22. Maximum and minimum delivery 
temperature

 

These two parameters limit the delivery temperature automatically produced

 

BY THE 4%-0%2!452% #/.42/, FUNCTION. 0!2!-%4%2 21 DETERMINES

 

-!8)-5- $%,)6%29 4%-0%2!452% (-!8)-5- (%!4).' 3%4 0/).4) 
while PARAMETER 22 determines MINIMUM DELIVERY TEMPERATURE 
(-).)-5- (%!4).' 3%4 0/).4).

 

PARAMETER 44. Enable thermoregulation function

 

The connected external temperature probe combined with PARAMETER 44 
provides the following operating modes:

 

%84%2.!, 02/"% #/..%#4%$ AND 0!2!-%4%2 44 = o (/&&) IN THIS 
CASE THE 4%-0%2!452% #/.42/, FUNCTION IS DISABLED EVEN THOUGH THE

 

external probe is connected. The temperature read by the external   probe

 

CAN ALWAYS BE VIEWED BY PRESSING THE ).&/ BUTTON. 4HE 4%-0%2!452%

 

#/.42/, SYMBOLS ARE NOT DISPLAYED.

 

%84%2.!, 02/"% #/..%#4%$,  0!2!-%4%2 44 = 1 (/.) IN THIS CASE 
THE 4%-0%2!452% #/.42/, FUNCTION IS ENABLED. 4HE TEMPERATURE READ 
BY THE EXTERNAL PROBE AND THE 4%-0%2!452% #/.42/, SYMBOLS CAN BE 
VIEWED BY PRESSING THE ).&/  BUTTON.

 

4HE 4%-0%2!452% #/.42/, FUNCTION CANNOT BE ENABLED UNLESS THE

 

external probe has been fitted and connected. In this case, PARAMETER 
44 is ignored and has no effect on boiler operation.

 

PARAMETER 45. Choosing the offset temperature curve (graph 1)

 

The offset heating curve maintains a theoretical ambient temperature of

 

2o

—# AT EXTERNAL TEMPERATURES RANGING FROM +2o—# TO -2o—#. 4HE CHOICE 

OF

 

the curve depends on the rated minimum external temperature (on the ge- 
ographical area, therefore) and the rated delivery temperature (on the type 
of system, therefore) and must be carefully calculated by the fitter using the 
following formula:

 

TO THE VALUE DETERMINED BY THE 4%-0%2!452% #/.42/, FUNCTION.

 

IF A PROGRAMMABLE TIMER IS CONNECTED TO THE BOILER, SET 
PARAMETER 51 = 1 (graph 3).

 

7HEN THE CONTACT IS CLOSED, THE HEAT REQUEST IS MADE BY THE DELIVERY PROBE ON

 

the basis of the external temperature in order to maintain the rated ambient

 

TEMPERATURE AT THE $!9 LEVEL (2o

—#). 7HEN THE CONTACT OPENS, IT DOES NOT

 

stop the heat request but reduces (parallel shift) the temperature curve to the

 

.)'(4 LEVEL (16

—#). 4HOUGH DELIVERY TEMPERATURE IS AUTOMATICALLY CALCULATED

 

by the boiler, the user may manually override it.

 

"Y MODIFYING (%!4).' ON THE USER INTERFACE, THE (%!4).' 3%4 0/).4 
WILL NO LONGER BE AVAILABLE BUT JUST A VALUE THAT CAN BE SET FROM +5 TO 
n5

—#

 

as required.

 

Modifications to this value do not directly change delivery temperature but 
affect the calculation made to automatically determine its value by modifying 
THE  REFERENCE  TEMPERATURE  OF  THE   SYSTEM (o = 2o

—# FOR  $!9 LEVEL; 16—# 

FOR

 

NIGHT level).

 

CONNECT AT/BT

 

)N CASE OF USING #/..%#4 !4/"4, ACCESSORY SUPPLIED ON REQUEST, THE BOILER

 

gives the possibility to choose 2 thermoregulation curves:

 

-  /4# 1 #( (PARAMETER 45) FOR A DIRECT SYSTEM

 

-  /4# 2 #( (PARAMETER 47) FOR A MIXED SYSTEM.

 

Even  in  case  of  second  circuit  (2CH)  the  curve  depends  on  the  external 
minimum project temperature (on the geographical area, therefore) and on 
the delivey project temperature (on the type of system, therefore); the installer

 

rated delivery T - 20

 

0. 47 = 1o X

 

20- rated min. external T

 

must to put attention to calculate it using the following formula:

 

Parameters 31 and 32 give the possibility to define the maximum and the 
minimum central heating set-point of the second circuit.

 

To correct the curve in this configuration, please refer to the instructions 
supplied with the accessory.

 

 

0. 45 = 1o X

 

rated delivery T - 20 20- 

rated min. external T

 

Type of building

 

 
 

 

 

 

 

 

 

D

 

17 

Содержание Exclusive GREEN HE C.S.I. 35 kW

Страница 1: ...DEL INSTALADOR Y DEL USUARIO PT MANUAL DO USUARIO E DO INSTALADOR HU TELEPiTOI ES FELHASZNAL6I KEZIKONYV RO MANUAL DE INSTALARE SI UTILIZARE SI NAVODILA ZA VGRADITEV PRIKLJUCITEV IN UPORABO PL INSTRUK...

Страница 2: ...2004 108 EEC Niskonapi ciowe wyroby elektryczne 2006 95 EEC Norma dotyczqca kotU6w kondensacyjnych 677 l w CE lnstrukcja instalacji i uzytkowania 148 Budowa kotUa 172 Obieg hydrauliczny 173 174 Schema...

Страница 3: ...trical devices or equipment such as switches appliances etc should not be used if there is a smell of gas or fumes If there is a gas leak open all the doors and windows to ventilate the area turn off...

Страница 4: ...DE P90 1 In this mode the modulating circulation unit works constantly at maximum speed It is used on plants with a high load loss in which the boiler s head must be used as much as possible in order...

Страница 5: ...articles After installation make sure that all the joints have been made airtight conforming to standard installation practices 7 ELECTRIC CONNECTION To access the electrical connections proceed as fo...

Страница 6: ...conditions C53 7ALL OR ROOF SEPARATE EXHAUSTION AND SUCTION IN DIFFERENT PRESSURE AREAS Exhaustion and suction must never be located on opposite walls C63 Exhaustionandsuctionwithseparatelycertifieda...

Страница 7: ...ic power 7 88 116 88 116 Category II2H3P II2H3P II2H3P II2H3P Supply voltage V Hz 230 50 230 50 230 50 230 50 Protection level IP X5D X5D X5D X5D Chimney losses with burner off on 0 10 2 16 0 08 2 30...

Страница 8: ...n revolutions at slow start revs min 3 700 3 700 Maximum number of fan revolutions revs min 6 000 6 000 Minimum number of fan revolutions revs min 1 200 1 900 EXCLUSIVE GREEN C S I 35 kW Diaphragm num...

Страница 9: ...le 4HE DISPLAY WILL LOOK LIKE IG 2 If the test is unsuccessful the boiler will not work and a 0 will flash on the display In this case contact the Technical Assistance Centre The boiler turns on in th...

Страница 10: ...tion has been made the modification is memorised and the display returns to the delivery temperature read by the probe Working the boiler Adjust the ambient thermostat to the required temperature appr...

Страница 11: ......

Страница 12: ...work at minimum power to increase the water temperature to a safe value 35 The symbol lights up on the display circulator anti block one operating cycle is performed every 24hours Switching off for lo...

Страница 13: ...INUTES THEWORDINGh3 vWILLAPPEARONTHEDISPLAY IG 16 AND THE hFUNCTION SELECTION INDICATORSv will light up in sequence Press button to stop the automatic vent cycle If you have to fill the system several...

Страница 14: ...nfo 5 displays the set heating temperature in reference to the second circuit only if it is connected S A R A function Fig 21 If the winter mode is selected the S A R A Automatic Ambient Adjustment Sy...

Страница 15: ...water gauge If the pressure is insufficient 0 4 bar red area proceed with the filling OPERATIONS DESCRIBED IN THE CHAPTER h ILLING AND EMPTYING THE SYSTEMSv F THE SYSTEM S PRESSURE IS SUFlCIENT o 6 B...

Страница 16: ...perations the select functions button acts as an ENTER confirm button the button acts as an ESCAPE escape button If no confirmation is given within 10 seconds the value is discarded and returns to the...

Страница 17: ...5 30 4 4 2 2 3 4 5 4 o 1 YES 0 31 8 5 4 3 4 0 4 2 CIRCUIT 40 80 45 32 5 4 3 4 0 4 2 CIRCUIT 20 39 25 40 7 4 2 34 4 0 2 4 o 1 54 2 1 41 4 3 0 2 4 2 3 4 53 4 3 4 9 1 42 3 2 5 4 o 1 54 1 43 4 3 0 2 4 2 3...

Страница 18: ...M DELIVERY TEMPERATURE 5 4 3 4 0 4 PARAMETER 44 Enable thermoregulation function The connected external temperature probe combined with PARAMETER 44 provides the following operating modes 84 2 02 4 AN...

Страница 19: ...n phases 4URN THE DOMESTIC HOT WATER SELECTOR TO SEQUENTIALLY SCROLL THE 2 4 3 26 PHASES 1 gas type don t modify this parameter 2 boiler power minor parameter 3 insulation level of building only if ex...

Страница 20: ...rm the value you have set by pressing ENTER XITTHE 2 4 3 26 FUNCTIONBYPRESSING 3 0 4HEBOILERRETURNSTOTHEh v STATUS To reset press the button Disconnect the pressure gauge and tighten the pressure tap...

Страница 21: ...sure the main heat exchanger is clean and free of any residuals or obstruction Check and clean where necessary the condensation trap to make sure it works properly lMPORTANT always switch off the pow...

Страница 22: ...e emissions Qnrisc 35 HE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 HEATING HEAT CAPACITY K7 Heat capacity curve fan rpm Qnrisc 35 HE 6500 6000 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000...

Страница 23: ...are SI SESTAVNI DELI KOTLA 1 Filling tap C S I 2 Pressuretransducer 3 Discharge valve 4 Three way solenoid valve 5 Safety valve 6 Circulation pump 7 Lower air vent valve 8 Hydrometer 9 Siphon 10 Retur...

Страница 24: ...bi boilers HE C S I EN MULTI WIREDIAGRAM ES ESQUEMA DE CONEXIONES 04 2 4 0 HU T BBVEZET KES RAJZ RO SCHEMA ELECTRICA MULTIFILARA SI ELEKTRI NA SHEMA PL SCHEMAT ELEKTRYCZNY COMBI BOILERS CSI With on de...

Страница 25: ...xternal connections inlow voltage M2 Terminal board supplementary pump connection M3 M6 Terminal board for external connections inhigh voltage M4 Terminal board water tank sensor connection R S I OPE...

Страница 26: ...he connections forthe low voltage functions to the 10 pole low voltage connections terminal board M10 as indicated in the diagram Fit the P O S DHW time clock as shown in the diagram after removing th...

Страница 27: ......

Страница 28: ...m ben RO dimensiuni in mm SI mere v mm PL wymiary w mm C B MB EN A condensate outlet C water gas ES A salida condensado C gas agua PT A sa da condensada C gua g s HU A kondenzvfz elvezetesIC vfz gaz R...

Страница 29: ...EXCLUSIVE GREEN HE C S I R S I 183 F R S I 1 9 C S I R S I C C A A D B F E D F 1 6 1 8 C S I E 1 7 A G F E 27...

Страница 30: ...R POWIETRZA DO SPALANIA Z POMIESZCZENIA 1 14 EN CONCENTRIC DUCT FOR FUMES OUTLET AIR INTAKE ES CONDUCTO CONC NTRICO PARA SALIDA DE HUMOS ENTRADA DE AIRE PT DUTO CONC NTRICO PARA SA DA DE FUMA A ENTRA...

Страница 31: ...T W SPALANIA M B D UGO PRZEWODU ZASYSANIA POWIETRZA m M F EXCLUSIVE GREEN 35 HE M M M F EN M spring F horizontal flap ES Muelle M F aleta horizontal PT mola M aba horizontal F HU M rug6 F vfzszintes z...

Страница 32: ...Registration of this product is required under the terms of warranty Please ensure you complete and return the commissioning declaration registration with this boiler to activate your warranty SERVIC...