High Traffic Shutdown Mode
To prolong battery life, the motion detector uses
a feature called
High Traffic Shutdown
. When
motion is detected, the device will transmit to the
receiver and will then shut down for three min-
utes. If motion is detected again during the shut-
down time, the unit will not transmit the event to
the receiver. The detector will thus remain in the
shutdown mode until three minutes after the first
motion detected was transmitted. The detector
will transmit detected motion every three minutes.
The
High Traffic Shutdown Mode
affects
testing the motion detector in two ways:
Ø
When performing the module
placement test
,
the unit must be tampered by removing the unit
from the backplate and placing it. The placement
test cannot be performed by creating motion in
front of the device.
Ø
When performing a
system test
, the unit must
be left idle for three minutes before testing can
be performed. Once three minutes has passed,
create motion in front of the detector to see if
the device is both detecting motion and trans-
mitting to the receiver.
n
n
Motion Detector Transmission Delay
A motion detector transmission is always delayed
by 6 seconds. This is necessary to prevent false
alarms caused by a motion sensor transmitting be-
fore a delay zone has a chance to report. This six-
second delay cannot be altered or disabled.
n
n
Walk Test Mode
The motion detector has a
Walk Test
mode
which will activate an LED for testing purposes.
During normal operation, the LED will not turn on.
To put the detector in
Walk Test
mode, create a
tamper by removing the detector from its backplate
and then replacing it.
Each time the detector senses motion, it will turn on
the red LED. Five seconds after motion is detected,
the detector will send a signal to the receiver, and the
LED will flash rapidly 5 times. The detector will be in
Walk Test
mode until it has sent 10 transmissions.
To verify the pet immunity of the detector place
the animal(s) within the coverage area and then
move out of the zone. Encourage the pet to move
around as it normally would and ensure that it
moves across the detection pattern of the detec-
tor. Verify that no alarm is initiated.
To test for catch performance of humans, cre-
ate motion in the entire area where coverage is
desired by walking perpendicular to the lens pat-
tern. Should the coverage be incomplete, readjust
or relocate the detector.
+
+
The Walk Test Mode will override the High
Traffic Shutdown Mode.
n
n
Battery Installation
This system is designed to work with Lithium
CR 123 A Batteries.
+
+
Do not install any other type.
The reliability of the security system depends
on its batteries, and "no name" or generic brand
batteries may not provide the best quality and de-
pendability. Use fresh batteries. Most batteries
have a "best before" date printed on their packag-
ing or on the batteries themselves. Buy batteries
that have a "best before" date of two years or
more from your purchase date.
Remove the motion detector from its mounting
plate by holding the sensor by its sides and pushing
up. Install one fresh Lithium CR123 A battery. Ob-
serve correct polarity when inserting battery (Fig. 4).
Replace the sensor on its mounting plate, making
sure it snaps into place. After the battery is in-
stalled, the detector will take 60 seconds to warm
up. During this time the LED will flash slowly.
+
+
The battery must be disposed properly.
Fig. 3
- Detection Pattern
“Fast” setting - 12 × 12
“Slow” setting - 10,60 × 10,60
APPENDIX
Fig. 4
- Battery installation
L I T H I U M
C R 1 2 3 A
3V
Содержание VectorBRIDGE