72
Universal Wireless Device System
VectorBRIDGE
Connection of the Universal terminal board to a Hardwired Control Panel
When connecting the Universal terminal board to a hardwired Control panel,
refer to the wiring diagram in Figure 8.
+
Use Shielded cable for the connection: connect one end of the shield to a
negative terminal (
M
terminals in Figure 8) on the Control panel, and leave the
other end free.
The Control panel and Interface must be programmed as follows.
The Interface Outputs must be Normally Closed (refer to “Standby for Outs” in
the “PROGRAMMING THE INTERFACE” section).
The Control panel Input lines (L1, L2, ..., L8) must be Normally Closed.
The Wireless Sensors must be assigned to Interface Outputs
A1
,
A2
,
A3
and
A4
(refer to “Zone Mapping” in the “PROGRAMMING THE INTERFACE” section).
Figure 8
Example of a connection of the Universal terminal board to a hardwired Con-
trol panel
L1 L2 L3 L4 L5 L6 L7 L8 AS
K
O1 O2 +B
A1 A2 A3 A4 A5 A6 A7 A8 TMP BAT MIS JAM KA KD KS KH MEM RES +12
tamper line
balance
resistor
Hardwired Burglar Panel
Interface
Содержание VectorBRIDGE
Страница 95: ......