n
Keyfob response
When executing a command, the keyfob’s transmission
LED blinks red once to indicate transmission of the
command to the control panel, then signals the out-
come of the command as described in the Table 9.
n
Sirens response
If set by the installer, the success and failure of arming
performed using the keyfob are indicated by the sys-
tem’s sirens as the following describes:
Ø
a short activation of wired sirens indicate that the
arming is successful
Ø
two short activations of wired sirens, or three short
activation of wireless sirens, indicates that arming is
refused due to blocking conditions
For more info, see “Arming block conditions” on
page 75.
Ï
Wired sirens connected to the Absoluta 630 control
unit do not signal the success and failure of the
arming carried out through the keyfobs.
+
Wireless sirens do not signal arming successful.
n
Status LED signals
The blue LEDs above the keyfob buttons show the sys-
tem status as the following table describes.
LED
Status
Away Armed
: at least one keyfob’s partition is
armed.
Mode A Armed
: the keyfob’s partitions are
armed and disarmed as set for mode A.
Disarmed
: all the keyfob’s partitions are dis-
armed.
n
Low Battery
If any of the keyfob batteries starts to run low, the
G
LED on the keypads will turn ON.
+
All the system trouble conditions are signalled by
the
G
LED. Therefore, if this LED turns ON, you
must access the
View Signals
mode for details.
The low wireless battery condition will be signalled in
View Signals
mode by the
Bat.low WLS
message
(refer to “OPERATIONS FROM TOUCH KEYPAD >
Viewing Signals” and “OPERATIONS FROM LCD
KEYPAD > Viewing Signal”).
The event logger will provide the details of the keyfob
that has triggered the low battery condition.
Read the instructions of the keyfob for battery replace-
ment.
64
Expandable Hybrid Control Panels
Transmission LED
signal
Buzzer signal
Description
Green blink
Success tone
Operation performed correctly.
Green blink
Five second sound
Forced arming: the control panel is not ready for arming
because there are block conditions, but the control panel
continues to arm (see "Arming block conditions" on
page 75).
Red blink
Failure tone
Operation not performed: there are conditions that prevent
the control panel from arming (see "Arming block condi-
tions" on page 75). Check on the keypad.
None
None
No communication: for example, the control panel is out of
range.
Yellow blinks for 2
seconds
Depends on the outcome
of the operation
Keyfob battery low: If the keyfob is still transmitting, de-
spite the conditions of the battery, the keyfob sends a low
battery message to the control panel
System trouble.
Table 9
Keyfob response: success tone = three short sounds followed by one long sound; failure tone = a long sound.
Содержание Absoluta 630 4.10
Страница 56: ...56 Expandable Hybrid Control Panels...
Страница 69: ...Absoluta Plus and Absoluta 630 TELEPHONE OPERATIONS 69...
Страница 82: ...82 Expandable Hybrid Control Panels...
Страница 83: ...Absoluta Plus and Absoluta 630 APPENDIX 83...