Press
OFF
to cancel the signals in a category (ONLY
Master User
with Grade 2 Control Panels and Alarms
in Grade 3 Control Panels or
Super User
with Grade 3
Control Panels).
Press
0
(zero) to reset the BPI bus when viewing tam-
pers and faults.
+
The keypad returns to the standby status 30 sec-
onds after you press the last key.
n
View partition status
The display shows the status of the partitions and other
information, as you can see follow and in Figure 3:
May/01/10
10:50
DDDDDDDDxxxxx**
1 2 3 4 5 6 7 8
S T b f s t r i
Ø
The
first 8
characters on the LCD bottom line show
the status of the partitions (Table 5 on page 38).
+
The keypad shows only the status of the partitions
common to the keypad and to the PIN used for ac-
cess.
+
The numbers below the display will correspond
only to the first 8 partitions.
Ø
The characters
n. 9 to 13
on the LCD bottom line
show the trouble conditions (Table 6 on page 38).
Ø
The
last three
characters on the LCD bottom line
shows the status of installer access, the answering
machine, and the communicator (Table 7 on
page 39).
The upper line of the display can shows the following
messages, with decreasing priority.
Ø
Service Jumper
when the control panel is in ser-
vice status (see “Service status” on page 36).
Ø
Out. silenced
when you silence the alarm out-
puts (see “Outputs (ON/OFF) (1.6)” on page 45).
Ø
SMS Received
when the GSM Module receives an
SMS message (see “Display SMS (3.4)” on page 54.
During the
view partition status
it is possible to perform
the basic operations.
Press
D
and
C
to scroll the keypad’s partitions, or press
the number corresponding to the desired partition.This
feature is available for only the first eight partitions.
38
Expandable Hybrid Control Panels
INITIAL
STATUS
DESCRIPTION
A
Away
The system will turn ON the perimeter and internal zones of the respective Partition.
P
Stay
The system will turn ON the perimeter zones of the respective Partition and will leave
the internal zones OFF.
Z
Stay - 0 Delay
The system will turn ON the perimeter zones of the respective Partition and will leave
the internal zones OFF, and will remove the Entry Time from zones which have one.
D
Disarm
The system will turn OFF the perimeter and internal zones of the respective Partition.
t
Test
At least one zone is in Test status for the relative partition.
*
Alarm Partition
The corresponding partition is in Alarm Status.
!
Alarm Memory
The corresponding partition has an Alarm in memory.
If the partition is selected, the letters will blink.
Table 5
Arming/Disarming Partitions.
ICON
SIGN
DESCRIPTION
S
X
ON
Control panel Tamper (Control panel open or dislodged).
Blinking
Control panel Tamper has cleared but at least one Open Panel event in memory.
T
X
ON
System Tamper.
Blinking
System Tamper has cleared but there is at least one System Tamper event in memory.
b
X
ON
Tamper on at least one peripheral device (keypad, reader, expander, or transceiver.
Blinking
Peripheral tamper has cleared but there is at least one peripheral tamper event in memory.
f
X
ON
A False Key/Card is present at a Reader.
Blinking
At least one False Key/Card event in memory.
s
X
ON
A peripheral device (keypad, reader, expander, transceiver, or wireless device) has
been disconnected.
Blinking
At least one Peripheral Trouble event in memory.
Table 6
Tamper signals.
1
3
5
7
2
4
6
8
05/May/10 *13:54
DDADDDAA X
* ÿ
Date
Partitions
Status
Scheduler enabled
if blinking
Time
Troubles
Tampers
Controls
Figure 3
The display of a LCD keypad during view par-
tition status (MAIN PAGE).
Содержание Absoluta 630 4.10
Страница 56: ...56 Expandable Hybrid Control Panels...
Страница 69: ...Absoluta Plus and Absoluta 630 TELEPHONE OPERATIONS 69...
Страница 82: ...82 Expandable Hybrid Control Panels...