Bennett CNG Spec. 100 Series Operators Manual
Programming
39
OPTION 2 – DECIMAL PLACE CONFIGURATION
The
Decimal Place Configuration
option allows the technician to choose the setting for two decimal places or three decimal places.
DECIMAL PLACE OPTIONS
2
– 100
th
(mass resolution – gallons “.01”)
3
– (Default) 1000
th
(mass resolution – gallons “.001”)
To configure the decimal place location in Menu Code 99, follow this procedure:
1.
To change the decimal placement, use the numeric keypad to select an option and
press [
ENTER
]. The display will show dashes during a new selection as shown in
Figure
4.64
.
Note
: If an error is made, press the correct number.
If the dispenser has not been programmed since it came from the factory then it
will be set for the default and decimal placement “
1000th
” appears in the main
display as shown in
Figure 4.66
. This is the default value.
The
0
(if new) or any other number that appears in the second row is a counter. It tracks the number of times this setting has
been changed.
2.
Press [
ENTER
] to save your setting and to cycle to the next option.
3.
Press [
CANCEL
] to exit this menu code.
OPTION 3 – TEMPERATURE UNIT CON FIGURATION
The
Temperature Unit Configuration
option allows the technician to choose the setting for degrees Celsius or degrees Fahrenheit as
temperature units.
Note:
For display and set point purposes.
TEMPERATURE OPTIONS
1
– Degrees Celsius
2
–(Default) Degrees Fahrenheit
To configure the temperature units in Menu Code 99, follow this procedure:
1.
To change the temperature unit, use the numeric keypad to select an option and
press [
ENTER
]. The display will show dashes during a new selection as shown in
Figure
4.67
.
Note
: If an error is made, press the correct number.
The
0
(if new) or any other number that appears in the second row is a counter.
It tracks the number of times this setting has been changed.
2.
Press [
ENTER
] to save your setting and to cycle to the next option.
3.
Press [
CANCEL
] to exit this menu code.
OPTION 4 – HOW TO VIEW THE ELECTRONIC CALIBRATION VALUES
The
Electronic Calibration Values
option allows the technician to view the current electronic calibration correction constant of each
configured meter as shown in
Figure 4.68
.
Note:
Values are unique to each meter.
To view the E-CAL Values in Menu Code 99, follow this procedure:
1.
Press the number
9
and
9
, then the [
MODE
]
button on the keypad. The PPM display shows the dispenser is in Menu Code 99.
Meter Calibration Value
Mass Adjustment
2.
After you press [
ENTER
]
,
you will be able to view the E-Cal values for each product as shown in
Figure 4.68
and the Meter Data as
shown in
Figure 4.69.
Press the [
ENTER
]
button to cycle through the E-Cal values.
Note:
The values are unique to each meter and side.
3.
Press the [
CANCEL
] button to exit this menu code.
FIGURE 4.68 – E-CAL VALUES
Sale $
0.00
GGE
Ecal 1a
0000
1A
Side 1
Product A
Sale $
AD1A
GGE
000
0001
FIGURE 4.69 – METER DATA
Sale $
1000TH
GGE
0
code
-99
FIGURE 4.66 – DECIMAL PLACEMENT
Sale $
c
GGE
0
code
-99
FIGURE 4.67 – TEMPERATURE UNITS
Содержание CNG Spec. 100 Series
Страница 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Страница 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Страница 10: ...Bennett CNG Spec 100 Series Operators Manual Safety Information 4 Page Intentionally Left Blank...
Страница 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Страница 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...