MENU CODE 85 - PRESSURE SET POINT
Menu Code 85 is used to input the pressure limit for the product lines. Exceeding pressure limit for 30 seconds will force the dispenser
into a paused state. The default pressure limit is P30 = 3600 psi or P36 = 4400 psi
TO ENTER THE PRESSURE SET POINT IN MENU CODE 85, FOLLOW THIS PROCEDURE:
1.
Press the number
8
and
5
, then the [
MODE
]
button on the keypad. The PPM display
shows the dispenser is in Menu Code 85 as shown in
Figure 4.64
. The default
pressure limit for P30 or P36 will be displayed.
2.
To change the setting, use the numeric keypad to enter a new option.
Note:
If an
error is made, press the correct number. The new number will replace the error.
3.
When the desired value appears in the main display, press the [
ENTER
] button to
save the selection.
4.
Press the [
CANCEL
] button to exit this Menu Code.
MENU CODE 99 –HOW TO CONFIGURE THE DISPENSER FOR UNIT OF MEASURE
IMPORTANT:
In order to program menu code 99 the electronic calibration switch must be flipped to E-Cal mode.
Menu Code 99 is used to set the unit of measurement used in the country where the dispenser is located. The second option allows the
technician to configure the decimal place location. The third option allows the technician to configure temperature units. The fourth
option is for viewing the electronic calibration settings. This menu code also uses a counter to track the number of times the unit of
measure, decimal placement, and temperature unit has been changed. Refer to options 1 through 4 for detailed descriptions and
programming instructions.
Note:
Press [
ENTER
] to cycle through the different available options. Use the numeric keypad to select an option.
OPTION 1
– Program the Unit of Measurement
OPTION 2
– Decimal Place Configuration
OPTION 3
– Program Temperature Units
OPTION 4
– View Electronic Calibration
OPTION 1 – PROGRAM THE UNIT OF MEASURE
The
Unit of Measure
identifies the unit of measure used in the country where the dispenser is located. There are six available options.
UNIT OF MEASURE OPTIONS
1
– (Default) GGE = Gasoline Gallon Equivalent
2
– GLE = Gasoline Liter Equivalent
3
– DGE = Diesel Gallon Equivalent
4
– DLE = Diesel Liter Equivalent
5
– KG = Kilograms
6
– LB = Pounds
To select the unit of measure in Menu Code 99, follow this procedure:
1.
Break the seal on the E-CAL switch and flip the switch to the calibration position.
2.
After the Manager’s Mode has been accessed, press the number
9
and
9
, then the [
MODE
]
button on the keypad. The PPM display shows the dispenser is in Menu Code 99.
If the dispenser has not been programmed since it came from the factory, disabled will appear in the main display. This is the
default setting.
The
0
(if new) or any other number that appears in the second row under the 1 is a counter. It tracks the number of times this
setting has been changed.
3.
To change the setting, use the
1
through
6
buttons on the keypad to enter a new option. The display will show dashes during a new
selection as shown in
Figure 4.65
.
Note
: If an error is made, press the correct number. The new number replaces the error.
4.
Press [
ENTER
] to save your setting and to cycle to the next option. The dashes will disappear after a selection is made and the display
moves to the Decimal Place Configuration.
5.
Press [
CANCEL
] to exit this menu code.
FIGURE 4.64 – PRESSURE LIMIT
Sale $
Press
GGE
4400
code
-85
Sale $
GGE
GGE
0
code
-99
FIGURE 4.65 – UNIT OF MEASURE
Содержание CNG Spec. 100 Series
Страница 3: ...Bennett CNG Spec 100 Series Operators Manual Bennett Limited Warranty i...
Страница 4: ...Bennett CNG Spec 100 Series Operators Manual ii Page Intentionally Left Blank...
Страница 10: ...Bennett CNG Spec 100 Series Operators Manual Safety Information 4 Page Intentionally Left Blank...
Страница 46: ...Bennett CNG Spec 100 Series Operators Manual Programming 40 Page Intentionally Left Blank...
Страница 56: ...Bennett CNG Spec 100 Series Operators Manual Diagnostics 50 Page Intentionally Left Blank...