22
ARC CONTROL UNIT
IMPORTANT, PLEASE READ CAREFULLY:
The radio receiver in this product is compatible only with the new ARC (Advanced Rolling Code) transmitters which, thanks to 128-bit encryption ensure
superior copy-security. Storing new ARC transmitters is quite similar to that of normal rolling code transmitters with HCS coding
1) DESCRIPTION AND INTENDED USE
Gear motor 24Vdc for heavy-duty sliding gates up to 1500 Kg for residential or industrial buildings, with built-in controller CP.B24 TURBO
We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the
Benincà products and accessories and the guide for compiling the technical file and documents required under Annex V of the Machinery Directive,
mandatory under the regulations in force..
2) SPECIFICATIONS
BULL 1224 TURBO
Motor power supply
115 o 230 Vac 50/60 Hz
Consumption
3A (230V) - 5A (115V)
Torque
20 Nm
Operating jogging
intensive use
Protection level
IP44
Operating temperature
-20°C / +50°C
Gate max. weight
1200 kg
Rack module
M4/M6 accessory - RI.P6
Opening speed
25 m/min
Noise level
<70 dB
Lubrication
GREASE
N° of storable TX
2048
Central control
CP.B24 TURBO
Weight
- kg
3) PRELIMINARY CHECKS
Before proceeding with installation, check the following:
- The structure (gate, pillar, guide rail) must be sturdy and stable.
- The guide rail and its wheels must be suitably sized and maintained to avoid excess friction during gate sliding.
- If available, check the CE declaration of conformity of the gate and perform the risk analysis according to the machinery directive.
- Check that the gate travel during opening/ closing is limited by sturdy mechanical stops.
QUICK PROGRAMMING
NOTE:
Quick programming conditions:
- Transmitter memory empty
- Autoset never run previously.
- Only valid with ARC (Advanced Rolling Code) transmitters
If you make a mistake during the quick programming procedure, you can disconnect the power supply and restart the procedure.
Quick programming steps
1 - Unlock the gate manually, put it in closed position with the relative end stop enabled, and lock the gate.
2 - Supply mains voltage.
3 - The flashing light turns on (make sure it is connected).
4 - The system starts saving the transmitters automatically and the control unit is put on hold, waiting for a transmitter.
To skip the quick programming step and proceed with manual programming press + and - (ESC) simultaneously.
5 - On display starts flashing the message
TX00
.
6 - Press the hidden key of the transmitter to be saved.
7 -
PUSH
appears on the display.
8 - Press the key you want to associate with the receiver.
9 - TX01 appears on the display (if the second transmitter
TX02
is present).
10 - Repeat steps 6 and 7 for the subsequent transmitters to store, up to 99, checking the increase on the display (example
TX15
).
11 - To go to the next
AUTOSET*
step, press the key of a previously memorised transmitter until
AUTO
appears on the display.
12 - The message
AUTO
appears on display and the gate automatically performs 3 manoeuvres by calculating the optimal opera-
ting parameters. If the autoset operation has been completed successfully, the gate stops in open position and the message
OK
appears on display.
The maximum time for programming the first transmitter is 60 seconds.
If necessary, proceed with the manual setup of PARAMETERS and LOGIC, depending on the type of installation.
*This function is
NEEDED
to set the optimal functioning values of the installation,
Содержание BULL 1224 TURBO
Страница 2: ...2 A B 1 200 245 316 400 300 215 400 34mm BULL PI Optional 40 3 1 8 2 0 4 7 0 1 8 0 2 3...
Страница 3: ...3 V Z R 4 7 B F T MIN 10 mm MAX 20 mm MIN 120 mm MAX 140 mm 5 6 R D R D...
Страница 5: ...5 12 13 14 C L 7 4 1 2 3 POWER 2 x 1 5 RG 58 5 4 x 0 25 4 6 5 2 x 0 25 3 x 0 25 15...
Страница 7: ...7 18 19 A B C...
Страница 75: ...75...