Reference Manual
Capacitor Bank Protect. Relay KSR1
Rev. 10
2018-09
6
3 Operation
3.1 Power supply
The KSR1 can be supplied by 40 – 250 V AC (45 – 65 Hz)
or 40 – 300 V DC.
Attention: The power supply must be connected as it is depicted on the rear side of the device. A wrong
connection can cause malfunctions or can damage the device.
3.2 Inputs
3.2.1
Measurement input
The KSR1 has a voltage input as well as a current input. Here, the possible voltage range is 0,1 – 20 V and the
measurement range at the current input is 15 mA – 5 A. Both ports can be used for monitoring purpose, but it is not
possible to use both inputs parallel!
3.2.2
Blocking input
All monitoring functions can be blocked via inputs DI1 and DI2. This is discussed in more detail later.
!